Firebox Liner Kit Information - kozy heat Alpha ALP-36-L Installation And Operation Manual

Direct vent gas fireplase
Hide thumbs Also See for Alpha ALP-36-L:
Table of Contents

Advertisement

FIREBOX LINER KIT INSTALLATION
FIRE RISK! DO NOT OPERATE THIS FIREPLACE WITHOUT A FIREBOX LINER KIT INSTALLED!
WARNING
Brick refractory panels act as insulation panels. Enamel panel kits include insulation panels for back and side walls.
NOTE
If converting to LP Gas, do so now before installing Firebox Liner Kit.
Brick Refractory Firebox Liner Kits include: (3) pc. Brick Refractory Firebox Liner (2) Exterior Side Panels
Enamel Firebox Liner Kit includes: (4) pc. Enamel Firebox Liner (3) firebox insulation panels (4) screws (3) Exterior Enamel Panels
BRICK REFRACTORY FIREBOX LINER KITS
1.
Remove firebox floor refractory.
2.
Install firebox back panel, making sure notched end is positioned inside channel located towards bottom of firebox.
3.
Install firebox side panels. Cut out sections positioned around baffle, angled ends at bottom of firebox. Secure with refractory clips
located at front corners of baffle. Loosen screws, adjust clips to secure panels, retighten screws.
4.
Reinstall firebox floor refractory.
5.
Attach exterior side refractory panels to component access doors.
ENAMEL FIREBOX LINER KIT
1.
Remove firebox floor refractory.
2.
Sandwich together back insulation panel with backside back enamel panel, making sure enamel panel top and bottom flanges wrap
around insulation panel. Position assembly against firebox back wall, insulation side against wall, notched end resting in channel
located towards bottom of firebox, side flanges facing forward.
3.
Sandwich together side insulation panels with backsides of enamel panels (mounting flange-enamel panel front). Install panel
assemblies with cut out sections positioned around baffle, angled ends at bottom of firebox. Align holes in panel flanges at bottom of
panels with holes in burner heat shield, secure with (4) screws provided. Secure panel tops with refractory clips located at front
corners of baffle. Loosen screws, adjust clips to secure panels, retighten screws.
4.
Install firebox floor enamel panel.
5.
Attach exterior enamel panel sections to hearth plate and component access doors.
Enamel Firebox Liner Kit Shown
Figure 28a
Enamel back panel (only)
side flanges face forward
Enamel side panel bottoms
(only) secured to burner
heat shield - (2) screws each
Refractory clip
(utilized in all firebox liner kit installations)
28
Baffle

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alpha-36-g

Table of Contents