To operate or test the VacuFlush head system, make sure that your fresh water tank is full of water. Make sure
that the DC main, fresh water, and head switches on the AC/DC panel are all in the on position. To flush the
VacuFlush head system, use your foot to depress the pedal at the base of the head. This action will pump fresh
water into the stool, empty the head and transfer all waste into the waste tank. When you release the pedal,
water will stop entering the stool and the flushing action will cease.
Dockside Discharge – When at a marina that offers dockside
discharge, the marina will provide the facilities needed to perform
this operation. You will not need to use the Tank Watch system
(optional equipment with overboard discharge). The stainless steel
fitting labeled waste is located amidships on the port gunwale.
Twist the cap to open the fitting and insert the hose provided by the
marina into the dockside discharge waste outlet to connect to your
marina's dockside discharge service facilities.
instructions provided by the marina to operate their equipment.

Overboard Discharge (Optional)

If you have selected this optional system, your boat is equipped to
offer you the option of using either dockside or overboard
discharge to pump out the waste tank. Before using the overboard
discharge system, be sure to check with your local authorities,
Coast Guard, local marina or your dealer for the rules and/or laws
that may apply specifically in your area.
You can check the waste level in the waste tank by monitoring the
lights on the Tank Watch 4 panel, which is located in the head
area. As waste enters the tank, the lights will change to indicate
the waste level (i.e., green for empty, yellow for low, orange for mid
level or red for full).
To operate the overboard discharge system, first make
sure that the DC main, fresh water, macerator and
head switches on the AC/DC panel are all in the on
position. Then, turn the key on the Tank Master 4
panel to the automatic position. The green light will
come on indicating that the system is working and
waste will begin pumping overboard via one of the thru
hulls located amidships on the side of the hull.
Once the tank level reaches the low level in the tank, the green light will go out and the system will turn off. You
will need to turn the key to the manual position to complete the pump out process.
If the system does not seem to be pumping properly (water should shoot out approx. 10 feet via the thru hull),
check for leaks, loose clamps, etc. Remove the starboard wall panel in the mid berth cabin to access the holding
tank. Then, check the hose connection to be sure that there is no leak.
Refer to the manual in your owner's packet supplied by the manufacturer of the VacuFlush system for specific
operating instructions.
Warning:
Waste in the holding tank can form methane, an explosive gas.
precautions when any maintenance is done to the sanitary system.

Cabin Appliances and Accessories

As standard equipment, your galley comes equipped with a direct current refrigerator and an alcohol/electric
stove. The following optional equipment is also available for installation in the main cabin:
Vacuum pump
Follow the
Macerator
pump
VacuFlush
holding tank
VacuFlush
holding tank
Vacuum
pump