Yealink W52P Configuration Manual page 16

Dect
Hide thumbs Also See for W52P:
Table of Contents

Advertisement

Step
System Configuration Items y0000000000<xx>.cfg
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Step 10
Step 11
BROADSOFT PARTNER CONFIGURATION GUIDE – YEALINK W52P IP DECT PHONE
©
2013 YEALINK
Command
Set Register Expire Timer.
account.Expire = 3600
Enable reliable response.
account.Enable 100Re = 1
Enable Session Timer.
account.EnableSessionTimer = 1
account.SessionExpires = 300
account.SessionRefresher = 1
Enable Call Waiting.
Features.Call_Waiting = 1
Features.Call_WaitingTone = 1
Enable MWI.
account.SubsribeMWI = 0
account.SubscribeMWIExpire = 3600
Enable negotiated DTMF type.
account.DTMFInbandTransfer = 1
Select Transport Type.
account.Transport = 0
Enable Feature Key Sync.
Features.BroadsoftFeatureKeySync
= 1
Purpose
Set the registration period.
Reliable provisional response
(PRACK) should be enabled.
Set the W52P IP DECT Phone to
enable Session Timer.
Session Refresher:
0 = uac
1 = uas
Set the W52P IP DECT Phone series
to enable Call Waiting and Call
Waiting Tone.
MWI: Solicited when setting
SubscribeMWI = 1.
MWI: Not solicited when setting
SubscribeMWI = 0.
Set the W52P IP DECT Phone to
enable inband or RFC 2833
negotiated DTMF.
Set the SIP transport:
Transport = 0 (UDP)
Transport = 1 (TCP)
Transport = 2 (TLS) (except T18P)
Transport = 3 (DNS-SRV) (except
T80P)
Enable Feature Key Sync (except
T18):
1: Enable
0: Disable
20-BD5392-00
PAGE 16 OF 54

Advertisement

Table of Contents
loading