Refi t and Check Window
1. Refi t the window with the bottom two bolts. The
bolts should be screwed in securely.
2. Refi t the top two bolts securing by turning them
through 90 degrees.
3. Pull the top of the window forward and release to
check that it opens slightly and returns confi rming
the good function of the spring-loaded mechanism.
4. Similarly check the bottom of the window by pulling
it forward and releasing.
5. Apply fi rm hand pressure around the window frame
to ensure the window is sealed tight against the
fi rebox.
DANGER
!
The window unit must be correctly installed,
fastened and sealed after servicing or serious
bodily injury and/or damage to the appliance
may result.
To ensure a safe operation:
• Double-check that the window frame is
correctly installed;
• Verify that the bolts and spring-loaded bolts
are hooked properly to the window tabs then;
• Pull out the top of the window and release it
to insure the springs return it;
• Ensure the window is sealed before operation.
WARNING
!
Failure to install the window correctly can
leak carbon monoxide, affect the performance
of the fi replace, damage components, cause
overheating resulting in dangerous conditions.
Damage caused by incorrect window installa-
tion is not covered by the Valor warranty.
Installation
6. If the Hot Glass Warning plate has been removed
from the front lower corner of the window,
reinstall it by sliding it between the glass and
the frame as indicated.
Safety warning plate