QUALIFIED
INSTALLER
• A non-combustible hearth is not necessary in front of this appliance.
• Note that the unit is installed at the framing stage and fi xed to framing using support angles. See page 30. Wall
fi nish is then installed over the support angles up to the black frame on the unit.
NOTE: If using a 613CCB front, refer to the kit's instruction manual for framing dimensions.
When the appliance is installed directly on carpeting, tile or other combustible material other than wood
fl ooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of
the appliance.
- 29-3/4" to wall finish
- 30-3/4" when using
645CFV Clearview Front or
673 Edgemont Front
- 36" when using
613CCB Contemporary Front
See installation manual
packed with front trim
FRAMING IN A CORNER
22
22
Framing
Wall Finish
16" min. straight out or off the top venting.
Allow for elbow if rear vent with rise.
45-1/2" (115.5 cm) min.
1-1/2"
(38 mm)
min.
clearance
33-3/4" to
header
This is the framing
width. Wall finish
to 32-3/16" wide.