Refi T And Check Window - Valor Legend G3.5 700JN Owner's Manual

Direct vent gas insert fireplace, natural/propane gas
Table of Contents

Advertisement

Refi t and Check Window
1. To facilitate the installation of the window, hook the
side spring-loaded levers to the side shrouds as
indicated so they are not in the way of the window
frame.
2. Place the window in its bottom railing and rotate its
top against the fi rebox. Ensure to remove any
coal particles in the railing before installing
the window.
Bottom railing
3. While you hold it, unhook the side levers from
the side shrouds and hook them into the window
brackets on each side.
Installation
Window
frame
4. Pull out the top of the window and release it to
ensure the springs return it.
5. Apply fi rm hand pressure around the window frame
to ensure the window is sealed tight against the
fi rebox.
DANGER
!
The window unit must be correctly installed,
fastened and sealed after servicing or serious
bodily injury and/or damage to the appliance
may result.
To ensure a safe operation:
• Double-check that the bottom of the window
frame is correctly installed in the bottom
support railing;
• Verify that the levers are hooked properly to
the window tabs then;
• Pull out the top of the window and release it
to insure the springs return it;
• Ensure the window is sealed before operation.
WARNING
!
Failure to install the window correctly can
leak carbon monoxide, aff ect the performance
of the fi replace, damage components, cause
overheating resulting in dangerous conditions.
Damage caused by incorrect window installa-
tion is not covered by the Valor warranty.
6. If the hot glass safety plate has been removed
from the front of the window, put it back in place
as indicated.
Safety warning plate
QUALIFIED
INSTALLER
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Legend g3.5 700jp

Table of Contents