5. Apply fi rm hand pressure around the window frame
to ensure the window is sealed tight against the
fi rebox.
DANGER
!
The window unit must be correctly installed,
fastened and sealed after servicing or serious
bodily injury and/or damage to the appliance
may result.
To ensure a safe operation:
• Double-check that the window frame is
correctly installed;
• Verify that the bolts and spring-loaded bolts
are hooked properly to the window tabs then;
• Pull out the top of the window and release it
to insure the springs return it;
• Ensure the window is sealed before operation.
WARNING
!
Failure to install the window correctly can
leak carbon monoxide, affect the performance
of the fi replace, damage components, cause
overheating resulting in dangerous conditions.
Damage caused by incorrect window installa-
tion is not covered by the Valor warranty.
6. If the Hot Glass Warning plate has been removed
from the front lower corner of the window,
reinstall it by sliding it between the glass and
the frame as indicated.
Safety warning plate
7. Replace the front or trim with the barrier screen
attached.
WARNING
!
FOR SAFETY PURPOSE, ensure the barrier
screen is re-installed on the fi replace front after
maintenance.
Owner's Information

Checking Pilot and Burner Flames

A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
Pilot Flame can be seen
between left front and top logs
Rock fuel bed
A black discoloration may form over time at the front
bottom of the 6-rock original fuel bed; this deposit
can be burned off by running the fi replace on a low
to medium setting fi re for 30 to 45 minutes. This
discoloration is unavoidable and will re-form again.
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl ammable vapors and liquids.
Inspect the vent terminal outdoors regularly to make
sure that snow, trees, bushes, leaves, or other objects
do not obstruct it.
Examine the vent system and terminal regularly. We
recommend annually.
Pilot fl ame
Thermocouple
Thermocouple
probe must be
probe must be
in flame
in fl ame
OWNER'S
INFORMATION
Correct Flame
Picture—Logs
Correct Flame
Picture—Rocks
left of fi rst rock
7 7