Chapter 8 Operation and Maintenance
Verify CPU Frequency selection in Setup
System Management Configuration changed
Invalid System Configuration Data
Operating system not found
Patch for installed CPU not loaded. Please run
the bios flash update diskette.
PCI system error BUS/DEVICE/FUNCTON
xxxxh
CPU had been changed - Run setup
No usable CPU
No usable system memory
Memory Redundancy Feature could not
configure the Mirror DIMMs
Memory Redundancy Feature could not
configure the spare DIMMs
218
table: List of POST error messages
Message
Description
The CPU is abnormal. Power off the server and turn it back on.
If the message still appears, check the error log and replace the
CPU if it is at fault. Or the baseboard must be replaced. Contact
an office listed in the "Contact Information" of the "Start
Guide".
If this is displayed right after changing the hardware
configuration, disregard it. If the same message is displayed
again, confirm the cable is correctly connected and change the
[Reset Configuration Data] setting to [Yes] on the "7.2.5
Advanced Menu" ( p.190) of the BIOS Setup Utility.
The system configuration is abnormal. Check that the
configuration is supported. If the message still appears even
though the configuration is supported, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
The OS used for start up cannot be found. Check that the cables
of each device are connected correctly. Or check that SAS/
RAID recognizes the device normally during POST.
Check the [Boot Sequence] setting on the "7.2.4 Boot Options
Submenu" ( p.188) in the [Main] menu of the BIOS Setup
Utility. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
Check that the correct CPU is installed. If the correct CPU is
installed and the message still appears, BIOS requires to be
updated. Update the BIOS using updating tool supplied with
new CPU. If the message still appears, select [Yes] for the
[Reset Configuration Data] setting on the "7.2.5 Advanced
Menu" ( p.190) of the BIOS Setup Utility. Nevertheless, if the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
The expansion card is abnormal. Replace the expansion card. If
the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of the
"Start Guide".
The CPU has been replaced. This message appears after the
baseboard or CPU is replaced. Select [Yes] for the [Reset
Configuration Data] setting on the "7.2.5 Advanced Menu"
( p.190) of the BIOS Setup Utility.
Installed CPU error. Replace the CPU. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of "Start Guide".
Memory error. Check the error log and replace the memory
module. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
Memory Mirroring cannot be configured. Confirm that the
memory bank that configures the mirror is the same capacity. If
the memory is installed properly, it must be replaced.
Memory sparing cannot be configured. Confirm that the
memory bank that configures the spare is the same capacity or
larger. If the memory is installed properly, it must be replaced.