Replacing The Psu During Redundant Operation - Fujitsu Primergy RX300 S4 User Manual

Hide thumbs Also See for Primergy RX300 S4:
Table of Contents

Advertisement

3
Install a new PSU or dummy unit.

6.8.4 Replacing the PSU during Redundant Operation

When an optional PSU is installed and the redundant feature is enabled, if one PSU fails, the lamp
(green) on the defective PSU turns off. The defective PSU can be replaced without shutting down the
server.
Be sure to install a new PSU after removing the defective PSU.
1
Unplug the power cable from the failed PSU inlet.
2
Remove the defective PSU.
"
How to remove the power supply unit" (p.178)
3
Install a new PSU.
"6.8.3 How to Install the Power Supply Unit" (p.177)
4
Connect the power cable to the inlet of the replaced PSU.
PRIMERGY RX300 S4 User's Guide