9,000 & 12,000 btuh Warning - Wait 10 minutes after power is disconnected before starting disassembly.
1. Before Disassembly
2. Remove top cover
Remove the screws connecting the top panel, left and right side
panel.
3. Remove handle
Remove the screws connecting the handle
Disassembly of Outdoor Unit
4. Remove panel and grille
Remove the screws holding the panel, Remove the screws con-
necting the panel grille and panel, then loosen clamp.
5. Remove top cover
Remove the screws holding the valve cover
Top
Panel
6. Remove handle
Remove the screws connecting the left side panel and condenser
support board.
Handle
Left side plate
Panel
Grille
Valve Cover
119