System Operation 9,000/12,000 btuh Models, cont.
Other Controls
Sleep Mode 3 (Customized Cycle)
You will be required to enter 8 room setpoint values for 8 hours of runtime. The last room setpoint value will be main-
tained until Sleep Mode is canceled.
In Sleep Mode 3, press the "Turbo" button to enter setup mode. The remote controller will display "1:00" in the time lo-
cation. Use the "+" and "-" buttons to select the desired room setpoint for the 1st hour of runtime, then press the "Turbo"
button to save the data.
The remote controller will display "2:00". Once again, use the "+" and "-" buttons to select the desired room setpoint for the
second hour of run time. Press the "Turbo" button to save the data.
Repeat this procedure for the remaining hours (total of 8). After all 8 settings have been saved, the remote controller will
automatically revert back to the standard time and temperature display.
At anytime, you may press the "ON/OFF", "MODE", "TIMER", "SLEEP" or "TURBO" buttons to cancel the Sleep Mode 3
7)Indoor Fan Control
The indoor fan can be set to Ultra High, High, Med, Low and Auto with the remote controller.
In auto mode, the following speeds will be set:
Cooling Mode
a) T
ambient >= T
indoor
b) T
- 20 F < T
setpoint
c) T
ambient <= T
indoor
T
preset
T
preset
T
preset
Fan Speed
Product Introduction
+ 20 F
fan will run on high speed
setpoint
,
ambient < T
indoor
setpoint
- 20 F
fan will run on low speed
setpoint
,
T
amb.
+ 20 F
-20 F
High
+ 20 F
fan will run on medium speed
,
Med.
Low
Off