Disassembly of Indoor Unit
9,000 & 12,000 btuh Warning - Wait 10 minutes after power is disconnected before starting disassembly.
3. Remove guide louver, continued
Step 2. Remove the rotating shaft of the big guide
lover from the groove, slightly bend the big guide
Big guide louver
louver to remove it.
Step 3. Remove the axial bushing of the small guide
louver
Axial bushing
Step 4. Remove the rotating shaft of the small guide
lover from the groove, slightly bend the small guide
louver to remove it.
Small guide louver
4. Remove panel
Step 1. Loosen the clamps of the panel to remove
panel.
97