Disassembly of Outdoor Unit, continued
9,000 & 12,000 btuh Warning - Wait 10 minutes after power is disconnected before starting disassembly.
13. Remove 4-way valve assembly
Properly remove refrigerant charge, then remove valve by heating
brazed joints and withdrawing pipe from valve.
4-way valve
14. Remove compressor
Remove the three screws holding the compressor.
Compressor
15. Remove valve assemblies and condensor
Remove the screws holding the condenser assembly, then remove
the screws holding the two valve assemblies.
Small valve
Large valve
Condenser assy.
121