Disassembly of Indoor Unit
9,000 & 12,000 btuh Warning - Wait 10 minutes after power is disconnected before starting disassembly.
6. Remove swing fan blade
Clamp
Swing connecting rod
Step 1. Remove the four screws holding the pro-
tective grille, then remove the grille. Loosen the
clamps holding the swing connector and remove
Protective grilles`
the connecting rod.
Step 2. Remove the clamps holding the swing fan
blade, then remove the blade
Clamps
Swing fan blade
99