Filter Maintenance and Emergency Operation
Cleaning Air Filter
Titanium Dioxide filter
(2nd Stage Filter)
Missing or Inoperative Remote Control
52
1. Remove the front panel as shown on the picture
in the left.
2. The first stage filter can be cleaned with a vacu-
um cleaner or by washing with a mild soap and
< 113º F water.
3. The second stage filter cannot be washed, use a
vacuum cleaner to clean any dust, lint, etc. The
filter is made up of Titanium Dioxide.
4. Recharge the Titanium Dioxide filter by placing
it in the Sun for 3-4 hours every
3-6 months.
Emergency Operation:
When the remote controller is lost or damaged,
please use the auto switch on the indoor unit.
Press the AUTO/STOP button to enter AUTO
mode.
Press the AUTO/STOP button again to turn the unit
off.