Disassembly of Indoor Unit
18,000 btuh Warning - Wait 10 minutes after power is disconnected before starting disassembly.
8. Remove evaporator sub-assembly
Refrigerant piping
Pipe clamp
Screw
Step 1. Remove the screws holding the pipe clamp.
Screws
Step 2. Remove the screws holding the evapora-
tor sub-assembly, slightly reposition the tubing to
Refrigerant piping
remove the evaporator.
Evaporator sub-assembly
109