Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling fi restops.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install wall shield and ceiling fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe could cause fi re.
HORIZONTAL
TERMINATION
PVI-SLP
ALLOWED
PVLP-SLP
ALLOWED
VENT
MODEL
SYSTEM
PVI-SLP
PRIMO48
PRIMO48ST
PVLP-SLP
PVI-SLP
PRIMO60
PRIMO60ST
PVLP-SLP
PVI-SLP
PRIMO72
PRIMO72ST
PVLP-SLP
WARNING! Risk of Fire! Vertical termination is NOT allowed with PVLP-SLP. Fire could occur.
*
NOTE:
PRIMO48/PRIMO48ST & PRIMO60/
PRIMO60ST = Each 1 ft. of vertical drop
decreases total allowable length by 2 ft.
PRIMO72/PRIMO72ST = Each 1 ft. of
vertical drop decreases total allowable length
by 3 ft.
NOTE: Maximum total vent run= Total vertical vent run + Total horizontal vent run
**= Horizontal termination allowed with both PVI-SLP and PVLP-SLP
NOTICE: If a pipe confi guration includes a
vertical component that goes downward, a
vertical component going back upward is not
allowed. Condensation will occur.
Figure 4.5
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. L • 2/16
APPROVED VENT SYSTEMS
VERTICAL
DVP VENT
TERMINATION
COMPONENTS
ALLOWED
ALLOWED
NOT ALLOWED
ALLOWED
APPROVED VENT MAXIMUMS
MAX. TOTAL
MAX. 90°
VENT RUN (FT.)**
ELBOWS
60
60
50
50
40
40
FROM
APPLIANCE
WARNING
SLP VENT
COMPONENTS
ALLOWED
ALLOWED
MAX. VERT.
DROP (FT.)
6
12*
6
12*
5
9*
5
9*
4
9*
4
9*
NOTE: The PVI-SLP and the PRIMO
appliance must be separated by a
MAXIMUM
minimum of 3 ft. of pipe. Refer to the
VERTICAL
DROP
PVI-SLP instructions included with the
PVI-SLP kit.
HORIZONTAL TERMINATION
PVI-SLP OR PVLP-SLP
FROM
APPLIANCE
ADAPTER KITS
PART NUMBER
PART DESCRIPTION
DVP-2SL
Adapts from 8 in. DVP-se-
(Included with
ries starting collars to 6-5/8
PRIMO)
in. SLP series vent pipe.
Adapts from 8 in. DVP-se-
DVP-SLP24
ries starting collars to 6-5/8
in. SLP series vent pipe.
VERTICAL TERMINATION
PVI-SLP ONLY
FROM
APPLIANCE
21