PRIMO48-CF, PRIMO48ST-CF, PRIMO60-CF, PRIMO60ST-CF, PRIMO72-CF, PRIMO72ST-CF
MODELS: PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST
Leave this manual with party responsible for use
and operation.
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
This
appliance
comes
SafeSurface
Glass which keeps the surface temperature
TM
of the barrier glass at a safe level and will still be hot to
the touch when operated for long periods of time.
If the barrier glass is removed, the inner glass temperature
will be very hot and cause burns.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
WARNING! Risk of Fire! Combustible materials MUST
NOT overlap or be placed behind a decorative front.
CAUTION! Do not install damaged components.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
appliance installation manual.
Note: To avoid potential damage to hearth pad or flooring,
protect area in front of fireplace by laying cardboard or
blanket down.
PRIMO CLEAN FACE FINISH
Installation Instructions
standard
with
patented
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
Heat & Glo • Primo Clean Face Finish Instructions • 2310-925 Rev. D • 8/15
Clean Face Finish (Black Glass Interior)
PRIMO48-CF
PRIMO48ST-CF
PRIMO60-CF
PRIMO60ST-CF
PRIMO72-CF
PRIMO72ST-CF
The PRIMO appliance can be fi nished with 1/2 inch
sheetrock. Non-combustible fi nishing is not required.
During operation, the sheetrock will remain cool to the
touch.
Facing and Finishing - General Information
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.).
Splatter Guard
The splatter guard is a piece of corrugated material
used to protect the appliance during the installation
process before fi nishing work on the whole hearth is
complete. A splatter guard is factory-installed on PRI-
MO models. Splatter guards must be removed before
appliance is fi red.
WARNING! Risk of Fire! Remove the splatter guard be-
fore lighting the appliance. Shut off gas to the appliance
when the splatter guard is in place to prevent accidental
operation.
Finishing Instructions
It is important to follow the framing and fi nishing instruc-
tions to ensure proper placement of fi replace into the sur-
rounding framing/fi nishing materials.
Wall sheathing materials 1/2 in. thick are specifi ed
in this installation manual to properly align with the op-
tional fi nishing methods offered with this appliance. The
PRIMO may be fi nished to the appliance opening with 1/2
inch thick sheetrock.
•
Ensure that the one inch back clearance and one inch
side clearances are maintained.
WARNING! Risk of Fire! Maintain specifi ed air space
clearances to combustibles. Inadequate air space could
cause overheating and fi re.
1