PVLP-SLP Minimum Horizontal Footprint
This diagram shows the scenario if the 12-1/2 inch measurement was not accommodated for prior to installation. The
PVLP-BEK may be installed in the 5 inch gap or a small bump out may be created on the exterior wall to accommodate
for the additional space needed.
H*
=12-1/2 inches if using PVLP-SLP plus one SLP elbow. This is the minimum vent confi guration and is composed
of the factory-installed 6 inch DVP component, DVP-2SLP converter, SLP90 elbow and PVLP-SLP termination cap.
EXTERIOR
5-1/2 IN.
SHEATHING
1/2 IN.
1 IN. MIN.
1/2 IN.
CLEARANCE
INTERIOR SHEATHING
The dimensions above assume:
• 2 in. X 6 in. exterior wall studs
• 1/2 in. thick interior and exterior wall sheathing material
Figure 3.6 PVLP-SLP Minimum Horizontal Footprint (PRIMO48, PRIMO60, PRIMO72)
C
D
B
D
Model
PRIMO48ST
PRIMO60ST
PRIMO72ST
Figure 3.7 Appliance Locations PRIMO48ST, PRIMO60ST, PRIMO72ST
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. L • 2/16
WALL TO CAP TRANSITION CAN
BE COMPLETED WITH PVLP-BEK
C
A
Inches
Millimeters
Inches
Millimeters
Inches
Millimeters
5 IN.
NOTICE: This See-Through appliance is
NOT designed or approved for an indoor/
outdoor application.
A
B
C
60-1/4
17-1/8
48
1530
435
1219
72-1/4
17-1/8
48
1835
435
1219
84-1/4
17-1/8
48
2140
435
1219
12-1/2 IN.
(TO BACK OF APPLIANCE)
SIDE VIEW
SLP90
DVP-2SL
FACTORY-
INSTALLED
DVP PIPE
12-1/2 IN.
D
1/2
13
1/2
13
1/2
13
13