Heat & Glo PRIMO48 Installation Instructions Manual

Heat-zone-primo series

Advertisement

MODELS: PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST
Leave this manual with party responsible for use
and operation.
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
This
appliance
comes
SafeSurface
Glass which keeps the surface temperature
TM
of the barrier glass at a safe level and will still be hot to
the touch when operated for long periods of time.
If the barrier glass is removed, the inner glass temperature
will be very hot and cause burns.
DANGER
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
WARNING! Risk of Fire! Combustible materials MUST
NOT overlap or be placed behind a decorative front.
CAUTION! Do not install damaged components.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
appliance installation manual.
HEAT-ZONE-PRIMO

Installation Instructions

standard
with
patented
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
TO TOUCH GLASS.
Heat & Glo • HEAT-ZONE-PRIMO Instructions • 2310-936 Rev. E • 7/16
HEAT-ZONE-PRIMO
WARNING! Risk of Fire! Either the HEAT-ZONE-PRIMO
or the HEAT-OUT-PRIMO PowerFlow™ Heat Manage-
ment System must remain ON during operation of the ap-
pliance. Overheating will occur. Appliance will shut down.
Introduction
The HEAT-ZONE-PRIMO PowerFlow™ Heat Management
System conveys warm air from the fi replace through air
ducts to remote locations in the same room or other rooms
in the building. Two HEAT-ZONE-PRIMO's must be installed
with the PRIMO appliance or the appliance will overheat.
Two HEAT-ZONE-PRIMO's are included in the kit.
Approvals
The fl exible duct used with the HEAT-ZONE-PRIMO is
manufactured and marked to the requirements of UL-181,
Class I air duct.
Operation
The HEAT-ZONE-PRIMO PowerFlow™ Heat Management
System is powered by a thermo switch. The system will
turn on approximately 10 minutes after the appliance is
turned on. The HEAT-ZONE-PRIMO accessory is tested
and safe when installed in accordance with this installa-
tion manual. It is your responsibility to read all instructions
before starting installation and to follow these instructions
carefully during installation.
Installation of this kit MUST be performed by a qualifi ed
service technician.
The HEAT-ZONE-PRIMO is carefully engineered and must
be installed only as specifi ed. If you modify it or any of its
components you will void the warranty, and you may possibly
cause a fi re hazard. Installation must be done according to
applicable local, state, provincial, and/or national codes.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo PRIMO48

  • Page 1: Installation Instructions

    HEAT-ZONE-PRIMO MODELS: PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Instructions HEAT-ZONE-PRIMO Leave this manual with party responsible for use and operation. WARNING! Risk of Fire! Either the HEAT-ZONE-PRIMO CAUTION! Risk of Cuts, Abrasions or Flying Debris. or the HEAT-OUT-PRIMO PowerFlow™ Heat Manage-...
  • Page 2: Possible Air Duct Runs/Locations

    WARNING! Risk of Fire! DO NOT block vents. Possible Air Duct Runs/Locations Overheating will occur. Appliance will shut down. Maximum Duct Run Total Length: 25 FT. Each WARNING! Risk of Overheating! Both HEAT-ZONE- Minimum Duct Run Total Length: 36 IN. Each PRIMO’s must be installed and operational.
  • Page 3: Preliminary Preparation

    Preliminary Preparation CAUTION! Do not install damaged components. Contents of HEAT-ZONE-PRIMO If any parts are missing or damaged, contact your dealer before starting installation. DO NOT install a damaged kit. DESCRIPTION SERVICE PART NO. 6 in. Round Duct 659-200 Fan Housing Assembly 659-001A Junction Box 659-122...
  • Page 4 • Install the HEAT-ZONE-PRIMO collars on the left and right sides of the appliance with screws. See Figure 3. • Attach included air duct to the HEAT-ZONE-PRIMO Fan Housing collars with gear clamps. See Figure 4. Mounting Bracket • Attach both mounting brackets to the fan housing. (Both Sides) See Figure 4.
  • Page 5 WARNING! Risk of Fire! The PowerFlow™ Heat 2 X 4 Wall Mounting Management system must remain ON during operation of the appliance. Overheating will occur. The appliance Note: The brackets can be rotated 180º and mounted to will shut down if the heat management systems are not the back side of the 2 x 4 if necessary.
  • Page 6: Electrical Connections

    Other Duct Options Plan the location of the fi replace and the warm air duct run(s). Metal Oval Air Duct: Attach the round-to-oval adapter to Electrical Connections the HEAT-ZONE-PRIMO collar with screws. Attach the 6" Wire 110-120 VAC service from the appliance to the junction oval duct to the adapter with screws.
  • Page 7 HEAT-ZONE-PRIMO Feature - Configuration HEAT-ZONE-PRIMO HEAT-ZONE-PRIMO HEAT-ZONE-PRIMO HEAT-ZONE-PRIMO Collar HEAT-ZONE-PRIMO Collar LED Color Switch Figure 10. HEAT-ZONE-PRIMO Configuration WARNING! Risk of Fire! Either the HEAT-ZONE-PRIMO or the HEAT-OUT-PRIMO PowerFlow™ Heat Manage- ment system must remain ON during operation of the ap- pliance.
  • Page 8 2155-204 LED SWITCH 2155-752 RC300 4.5V DC 2155-755 (AAA X 3) JUNCTION BOX 2310-211 2273-308 2300-753 JUMPER WIRE LED’S 2310-062 2310-200 (PRIMO72ST ONLY) 2273-308 2310-211 SEE THROUGH ONLY 2310-204 THERMODISC 2005-021 WIRE PLUG 2166-335 AUX 2196-150 ASSEMBLY PVI MODULE HEAT-ZONE-PRIMO PVI-WHXX 2196-200 PVI-WIRE HARNESS BROWN...

This manual is also suitable for:

Primo60Primo48stPrimo60stPrimo72Primo72st

Table of Contents