Install the HEAT-ZONE-PRIMO collars on the left and
right sides of the appliance with screws. See Figure
6.7.
Attach included air duct to the HEAT-ZONE-PRIMO
collars with gear clamps. See Figure 6.8.
Attach both mounting brackets to the fan housing.
See Figure 6.8.
Mount fan housing in desired location. See Figures
6.5, 6.10 and 6.11.
Attach round to oval adapter to fan housing with two
screws. See Figure 6.8.
Attach included fl exible ducts to round to oval adapter
with gear clamps.
Note: 6 Inch metal duct can be used in place of the in-
cluded fl exible ducts.
WARNING! Risk of Fire! HEAT-OUT-PRIMO seal plates
MUST remain installed. Appliance could overheat.
HEAT ZONE
®
COLLAR LOCATION
LEFT AND RIGHT SIDES
DO NOT
REMOVE
KNOCKOUTS
Figure 6.7 HEAT-ZONE-PRIMO
WARNING! Risk of Fire! DO NOT fold/kink/pinch/ob-
struct 6 inch fl exible ducts. Appliance could overheat.
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. L • 2/16
30
SQUARE
VENT
PIPE GASKET
Figure 6.8
HEAT-OUT-PRIMO
SEAL PLATES
MINIMUM SPACE
90 DEGREE BEND
Figure 6.9
Mounting Bracket
(Both Sides)
Screws
Gear Clamp
18 in.
REQUIRED FOR
Fan Housing
Round to Oval Adapter
Gear Clamp
6 in. Round Air Duct
6-3/4 in.