Installation distances

C26T Low
Combustible roof
582
G 90
Permitted area for
combustible material
Fire-retardant wall of
brick or concrete
300*
*To prevent discolouration of painted fire walls, we recommend the same side distance as to combustible walls.
A = height from floor to chimney connection upwards
B = height from floor to c/c chimney connection rear
C = distance from back to c/c chimney connection upwards
D = distance from back to chimney connection rear
E = distance from back to hole in guide plate
F = height from floor to air inlet connector (410 mm)
G = distance to hole in guide plate
Combustion air hose
(accessory)
500
400
300
200
Combustible wall
600
890
590
502
462
C 188
D 85
Utv Ø150
E 150
Combustible wall
Fire-retardant wall of
brick or concrete
INSTALLATION DISTANCES
Place the stove on the
hearth plate and check
that the installation
distances are not less
than those that are given
in the figures below. The
minimum distance in
front of the stove opening
to combustible parts of
the building or interior
decoration must be at least
1 m.
When top connecting
a steel flue, please
refer to the particular
manufacturer's installation
instructions. Observe
the safety distance to
combustible material that
the steel flue requires.
GB
55

Hide quick links:

Advertisement