  • Page 1 Installation instruction C 35T www.contura.eu...
  • Page 2 See rating plate on the stove Intended area of use Heating of rooms in residential buildings Fuel Wood MANUFACTURER Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden CHECKS According to AVCP System 3 European standard...
  • Page 3: Table Of Contents

    A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new stove. As a new owner of a Contura stove, you have secured a product with timeless design and long service life.
  • Page 4: Technical Details

    FACTS Technical details Important to remember! Installation by authorised Structural support Effect 3-7 kW Nominal effect 5 kW technician Check that the wood joists are strong Efficiency 80 % enough to bear the weight of the stove This manual contains instructions on and chimney.
  • Page 5: Installation Distance To Walls And Ceiling

    INSTALLATION DISTANCES Installation distance to walls and ceiling C 35T Combustible roof The minimum distance in front of the stove opening to combustible parts of the building or interior decoration must be at least 1 m. The dimension diagrams only...
  • Page 6: Supply Of Combustion Air

    SUPPLY AIR/ACCESSORY Supply of combustion air Combustion air can be provided directly via a duct from outside, In hot areas, the duct has to be insulated with 30 mm mineral wool or indirectly via a vent in the outer wall of the room where the covered with a moisture barrier (plastic).
  • Page 7 SUPPLY AIR/ACCESSORY Self-closing door The stove is equipped with a spring to close the door automatically. The spring is situated above the heat deflector. The closing force of the hatch can be adjusted by moving the spring between the three notches on the lever. The angle of the stove also affects the closing force of the spring.
  • Page 8: Connection To Chimney

    CHIMNEY Connection to chimney • The stove meets the requirements for connecting to chimneys • A flue with sharp bends and horizontal routing reduces the dimensioned for flue gas temperatures of 350°C. draught in the chimney. The maximum horizontal flue is 1 m, on the condition that the vertical flue length is at least 5 m.
  • Page 9 Sweeping When sweeping, the smoke baffle must be removed; on the Contura 30 series this can be done by lifting the smoke baffle and removing the side piece. Lift the smoke baffle out and remove the remaining sections. Handle the parts with care.
  • Page 10: Installation Of Surround

    INSTALLATION Installation of surround F1 603492 F2 603655 The stones are numbered as illustrated above. We recommend F1 603488 (B 403967) that the stones be installed in the order described on the following F2 603650 pages. F1 603495 (B 403957) F2 603658 Take care of the soapstones! (B 403970)
  • Page 11 INSTALLATION...
  • Page 12 INSTALLATION If a fan is to be installed, it has to be done before the lower front stone is put in place. Check that the front stone is positioned level with the sides of the base plate.
  • Page 13 INSTALLATION...
  • Page 14 INSTALLATION Clean the inner and outer side glass before further installation. Carefully insert the profile and glass and move down the groove.
  • Page 15 INSTALLATION...
  • Page 16 INSTALLATION Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used. Also read the ”Lighting instructions”, before lighting for the first time.
  • Page 17: Installation Of Accessories – Heat Retaining Stones

    INSTALLATION Installation of accessories – Heat retaining stones Heat retaining stones to glass top...
  • Page 18 INSTALLATION Heat retaining stones to soapstone top...
  • Page 19 INSTALLATION...
  • Page 20 NIBE AB · Box 134 · 285 23 Markaryd · Sweden www.contura.eu Contura reserves the right to change dimensions and procedures described in these instructions at any time without 811184 IAV SE-EX C35T-6 special notice. The current edition can be downloaded from 2015-10-22 www.contura.eu...