Fault code No.
Item
1
Connection of coolant tem-
perature sensor coupler.
Check the locking condition
of the coupler.
Disconnect the coupler and
check the pins (bent or bro-
ken terminals and locking
condition of the pins).
2
Connection of wire harness
ECU coupler.
Check the locking condition
of the coupler.
Disconnect the coupler and
check the pins (bent or bro-
ken terminals and locking
condition of the pins).
3
Wire harness continuity.
4
Installed condition of coolant
temperature sensor.
Check for looseness or
pinching.
5
Defective coolant tempera-
ture sensor.
6
Malfunction in ECU.
Fault code No.
Item
Fail-safe system
Diagnostic code No.
Meter display
Procedure
Probable cause of mal-
Item
function and check
email: info@motomatrix.co.uk
21
Coolant temperature sensor: open or short circuit detected.
Improperly connected →
Connect the coupler secure-
ly or repair/replace the wire
harness.
Improperly connected →
Connect the coupler secure-
ly or repair/replace the wire
harness.
Open or short circuit → Re-
place the wire harness.
Between coolant tempera-
ture sensor coupler and ECU
coupler.
green/white–green/white
black/blue–black/blue
Improperly installed sensor
→ Reinstall or replace the
sensor.
Execute the diagnostic
mode. (Code No. d:06)
Replace if defective.
Refer to "CHECKING THE
COOLANT TEMPERATURE
SENSOR" on page 8-152.
Replace the ECU.
22
Intake air temperature sensor: open or short circuit detected.
Able to start engine
Able to drive vehicle
d:05
Displays the intake air temperature.
Compare the actually measured intake air temperature with the
meter display value.
Maintenance job
8-43
FUEL INJECTION SYSTEM
Set the main switch to "ON".
Fault code number is not dis-
played → Service is finished.
Fault code number is dis-
played → Go to item 2.
Set the main switch to "ON".
Fault code number is not dis-
played → Service is finished.
Fault code number is dis-
played → Go to item 3.
Set the main switch to "ON".
Fault code number is not dis-
played → Service is finished.
Fault code number is dis-
played → Go to item 4.
Set the main switch to "ON".
Fault code number is not dis-
played → Service is finished.
Fault code number is dis-
played → Go to item 5.
Set the main switch to "ON".
Fault code number is not dis-
played → Service is finished.
Fault code number is dis-
played → Go to item 6.
Confirmation of service
completion