Yamaha XT1200Z 2010 Service Manual page 246

Table of Contents

Advertisement

Manuals by Motomatrix / www.motomatrix.co.uk / The Solution For Lost Motorcycle Coded Keys
• If the pulse is hardly felt in either the brake
lever or brake pedal, check that the brake
hoses and brake pipes are connected cor-
rectly to the hydraulic unit assembly.
• If the operation of the hydraulic unit is normal,
delete all of the fault codes.
8. Release the brake lever and brake pedal, and
then set the main switch to "OFF".
ECA23P1089
NOTICE
If the main switch is set back to "ON" while
the brake lever and brake pedal are operated,
the hydraulic unit operation test cannot be
restarted.
Hydraulic unit operation test 2
EWA13120
WARNING
Securely support the vehicle so that there is
no danger of it falling over.
1. Place the vehicle on the centerstand.
2. Set the main switch to "OFF".
3. Remove:
• Rider seat
• Right side cowling
Refer to "GENERAL CHASSIS" on page 4-1.
4. Check:
• Battery voltage
Lower than 12.8 V → Charge or replace the
battery.
Battery voltage
Higher than 12.8 V
TIP
• If the battery voltage is lower than 12.8 V,
charge the battery, and then perform hydraulic
unit operation test 2.
• If the battery voltage is lower than 10 V, the
ABS warning light comes on and the ABS does
not operate.
email: info@motomatrix.co.uk
ABS (Anti-Lock Brake System)
5. Remove the protective cap and then connect
the test coupler adapter "1" to the ABS test
coupler "2".
Test coupler adapter
90890-03149
6. Set the engine stop switch "1" to "
7. Set the main switch to "ON".
8. Push the start switch "1" for at least 4 sec-
onds.
ECA14790
NOTICE
Do not operate the brake lever or the brake
pedal.
4-73
2
1
".
1
1

Advertisement