Convergence Controls - Barco DP2K-32B Installation Manual

Hide thumbs Also See for DP2K-32B:
Table of Contents

Advertisement

12.3 Convergence controls

Definitions-Abbreviations
X: Horizontal direction on the screen, with origin in the centre of the screen and + to the right
Y: Vertical direction on the screen, with origin in the centre of the screen and + to the top
Z rotation: Tilting of the X and Y axes in their plane: + is clockwise rotation
[1] ; [2] ; [3] ; [4] ; [5] ; [6] : these are the 6 adjustments available as they appear on the standard convergence adjustment
screen.
Convergence controls, location
Image 12-5
Convergence knobs
1
Red channel, knob number 1
2
Red channel, knob number 2
3
Red channel, knob number 3
4
Green channel, knob number 4
5
Green channel, knob number 5
6
Green channel, knob number 6
Convergence Test pattern
For the manual correction of the DMD convergence, a typical convergence test pattern is generated.
R59770491 DP2K-32B 30/04/2010
1
2
3
6
5
4
12. Convergence
123

Hide quick links:

Advertisement

Table of Contents
loading