3. Physical installation
3.5

Connecting the projector with the power net

W
ARNING
ble disconnect switch, circuit breakers and ground fault current interrupters. The installation shall be done
according to the local electrical installation codes.
W
ARNING
C
AUTION
or AWG 10
Necessary tools
Flat torque screw driver 4 mm
Adjustable wrench
Necessary parts
Certified power cable min. 4.0 mm², 10AWG. 500V (for 3W+N+PE), cable diameter between 11mm and 21 mm or
Certified power cable min. 4.0 mm², 10AWG 300V (for 3W+PE) cable diameter between 11mm and 21 mm
Circuit breaker maximum 40A
How to connect
1. Remove the back cover.
2. Remove the power input cover.
3. Loosen the cable gland fixation ring (1).
Note: The cable gland (1) is specified for cables with a diameter between 11mm and 21mm.
Image 3-12
Power cable connection
4. Push the stripped power supply cable through the cable gland. When using a flexible power cord, make sure that each conductor
end is provided with an end sleeve.
Fix the cable in the cable gland by securing ring 1 with an adjustable wrench.
5. Connect the power cord with the terminal barrier strip. Use a flat torque screw driver set to 2 Nm.
Always connect the ground wire (PE) with the connector indicated with PE on the terminal barrier strip.
26
:
The total electrical installation should be protected by an appropriate rated and readily accessi-
:
Make sure that the voltage range of projector matches with the voltage of the local power net.
:
The cross-sectional area of the conductors in the Power Supply Cord shall be not less than 4 mm