2. General
2.1

Installation requirements

Environment conditions
Table below summarizes the physical environment in which the DP2K-32B may be safely operated or stored.
Environment
Ambient Temperature
Humidity
Altitude
Let the projector acclimatise after unpacking. Neglecting this may result in a startup failure of the Light Pro-
cessor Unit.
Cooling requirements
The projector is fan cooled and must be installed with sufficient space aroundthe projector head, minimum 20 cm (8 inch) to ensure
sufficient air flow. It should be used in an area where the ambient temperature, as measured at the projector air inlet , does not
exceed +35°C (+95°F).
The installation of an exhaust system is MANDATORY. The installed exhaust blower must remove an air volume of minimum 10
m
/min (350 CFM) measured at the exhaust output of the projector.
3
Main Power requirements
The DP2K-32B operates from a nominal 230/400V 3W+N+PE 15A 50-60Hz (Y connection) or 208V 3W+PE 25A 50-60Hz (Δ con-
nection). The projector must be switched internally between a star connection to a delta connection or vice versa. See "Power input
setup", page 24.
For a 3W+N+PE system, 400V is measured between the lines, 230V is measured between the lines and the neutral.
For a 3W+PE system, 208V is measured between the lines.
The power cord required to connect the projector with the power net is not delivered with the projector. It is the responsibility of the
customer to provide the correct type of power cord. The cross-sectional area of the conductors in the power supply cord shall not be
less than 4 mm² or 10 AWG, minimum 300V for a 3 x 208V AC (3W+PE) or minimum 500V for a 3 x 400V AC + Neutral (3W+N+PE).
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that the instrument panel
and cabinet be grounded. In no event shall this projector be operated without an adequate cabinet ground connection.
The AC supply must be installed by a qualified electrician in conformance to local codes. Hardware, wire sizes and conduit types
must comply with local codes.
A readily accessible disconnect device shall be incorporated externally to the equipment for removal of the power to the equipment
mains terminals.
The building installation must be provided with a circuit breaker of max. 40A to protect the complete unit.
W
ARNING
of all power from the unit
UPS requirements
The Uninterruptible Power Supply (UPS), also known as a Continuous Power Supply (CPS), must have an output voltage of 200-
240V at 50-60Hz and must be capable of delivering an output current of 5,5 amperes.
The connection between the UPS unit and the UPS inlet of the projector must be done with a certified AC power supply cord of
minimum 0,75 mm² or 18 AWG and minimum 300V.
C
AUTION
unit with power! The UPS OUTLET of the projector may only be used for connection to the UPS INLET of the
projector.
The DP2K-32B does not have a built in UPS unit.
10
Operating
10 °C (50 °F) to 35 °C (95 °F)
5% to 85% RH Non-condensed
-60 (-197Ft) to 3000m (9843Ft)
:
Disconnect the power to the unit mains terminals and unplug power cord at UPS inlet for removal
:
The 200–240V power outlet (UPS OUTLET) of the projector may not be used to provide the UPS
Non-Operating
-15°C (5°F) to 60°C (140°F)
5% to 95% RH Non-Condensed
-60 (-197Ft) to 10000m (32810Ft)