Console Port Login Configuration With Authentication Mode Being Scheme; Configuration Procedure - H3C S5120-SI Series Operation Manual

Hide thumbs Also See for S5120-SI Series:
Table of Contents

Advertisement

[Sysname] user-interface aux 0
# Specify to authenticate the user logging in through the Console port using the local password.
[Sysname-ui-aux0] authentication-mode password
# Set the local password to 123456 (in plain text).
[Sysname-ui-aux0] set authentication password simple 123456
# Specify commands of level 2 are available to the user logging in to the AUX user interface.
[Sysname-ui-aux0] user privilege level 2
# Set the baud rate of the Console port to 19200 bps.
[Sysname-ui-aux0] speed 19200
# Set the maximum number of lines the screen can contain to 30.
[Sysname-ui-aux0] screen-length 30
# Set the maximum number of commands the history command buffer can store to 20.
[Sysname-ui-aux0] history-command max-size 20
# Set the timeout time of the AUX user interface to 6 minutes.
[Sysname-ui-aux0] idle-timeout 6
After the above configuration, to ensure a successful login, the console user needs to change the
corresponding configuration of the terminal emulation program running on the PC, to make the
configuration consistent with that on the switch. Refer to
for details.
Console Port Login Configuration with Authentication Mode Being
Scheme

Configuration Procedure

Follow these steps to perform Console port login configuration (with authentication mode being
scheme):
Setting Up the Connection to the Console Port
2-11

Advertisement

Table of Contents
loading

Table of Contents