Static Generator Values Kokusan 4K3B - HUSABERG FE 450 Repair Manual

Hide thumbs Also See for FE 450:
Table of Contents

Advertisement

STATIC GENERATOR VALUES - KOKUSAN 4K-3B
Measuring conditions:
– Cold engine
– Seat and tank removed
– All plugs and the ground connections are in a non-corroding condition, plugs are tightly connected
– Battery charged (if installed) and the light switch turned off
– Decompression lever is pulled
– Depress the kickstarter forcefully at least 5 times for each measurement
Check the generator outlet (also see circuit diagram on
opposite page) for voltage between the following cable
colors:
– Between yellow and brown (ground), plug (7)
disconnected
Multimeter reading: 12 volts +/- 1 volt
– Same measurement with plug (7) connected
Multimeter reading: 12 volts +/- 1 volt
– Between
white
F
disconnected
Multimeter reading: 19 volts +/- 1 volt
10
– Same measurement with plug (8) connected
Multimeter reading: 15 volts +/- 1 volt
NOTE: apply the black measuring tip on the
peak voltage adapter to the ground.
Check the regulator output voltage (9) (also see circuit
diagram on opposite page) with the cable color
yellow/red, controller (10) connected, fuse (11) removed:
– Between yellow/red and brown (ground)
Multimeter reading: 14 volts +/- 1 volt
NOTE: apply the black measuring tip on the
peak voltage adapter to the brown (ground)
cable.
ELECTRIC SYSTEM
and
brown
(ground),
plug
(8)
9
8
7
10

Advertisement

Table of Contents
loading

Table of Contents