Symptom: Battery Becomes Discharged - Buell XB9R 2003 Service Manual

Hide thumbs Also See for XB9R 2003:
Table of Contents

Advertisement

HOME
Test 7.6 (Part 1 of 2)

SYMPTOM: BATTERY BECOMES DISCHARGED

Test voltage regulator. See
Voltage Regulator Bleed
Perform
Test
Perform
Test. Record measurement.
7-20
2003 Buell XB9R: Electrical
Charge or replace as required.
See
See REGULATOR INSPECTION.
Voltage Regulator
PASS
Test.
PASS
Milliampere Draw
(If applicable).
PASS
Total Current Draw
PASS
STOP
Go to
Test 7.6
(Part 2 of 2).
Whenever a charging system component fails a test and
is replaced, re-test the system to be sure the problem
has been corrected.
Test battery.
See
7.10 BATTERY.
Inspect regulator.
Inspect regulator.
Inspection.
NOTE
FAIL
Correct as
required.
5306
FAIL
Replace regulator.
5316
FAIL
Isolate damaged
component or wiring.
5308
FAIL
Isolate damaged wiring or
excessive accessories.
5310

Advertisement