Buell XB9R 2003 Service Manual page 322

Hide thumbs Also See for XB9R 2003:
Table of Contents

Advertisement

HOME
Test 4.11 (Part 1 of 3)
Is fresh gasoline in tank?
YES
Check for trouble codes. See
CHECKING FOR TROUBLE
CODES. Codes found?
NO
YES
Refer to applicable
trouble code chart.
Start with lowest
code
No pump response or light.
See to
4.12 NO ECM
Short pump response, light OK.
See
4.34 BANK ANGLE
NO
Fill tank with
4.4
fresh gasoline.
Connect Breakout Box. Measure
1
voltage between connector 10 (BK)
pin 10 (+) and pin 11 (-) Voltage
should be 0.25-2.7 volts (Run
Check battery connections.
Check battery voltage. Is voltage
2
Place transmission in neutral. Turn ignition
key switch ON and set engine stop switch to
RUN. Did fuel pump run 2-3 seconds and
check engine lamp illuminate?
NO
POWER.
NO
SENSOR.
Install Fuel Pressure Gauge. See
SURE
TEST. While cranking engine (for more than
two seconds to ensure proper system operation),
verify that pressure rises to 49-51 PSI (338-352 kPa).
Adequate pressure?
Go to
Test 4.11
(Part 2 of 3).
Mode). Is it?
YES
above 12.8 volts?
YES
Does battery pass
load test?
YES
NO
NO
See
YES
4.13 FUEL PRES-
YES
STOP
NO
See
4.26 TROUBLE
CODE
44.
NO
Recharge
2
battery.
7180
NO
Replace
2
battery.
7185
No pump response, but light OK.
See
4.13 FUEL PRESSURE
TEST.
Pump OK, but no light.
4.9 CHECK ENGINE LAMP NOT ILLUMI-
NATED AT KEY
ON.
NO
Incorrect pressure. See
4.13
FUEL PRESSURE
TEST.
7195
2003 Buell XB9R: Fuel System
7190
4-25