Service Mode 2; Accessing Fault Codes; Table 6-10: G 848 Service Mode 2 Functions - Miele G 600 Series Technical Information

(all us models)
Hide thumbs Also See for G 600 Series:
Table of Contents

Advertisement

Technical Information
6.8.2.3

Service Mode 2

Service Mode 2 is used to determine which upper electronic is in the machine, to
change certain programmed functions and to access fault codes. The programmed
functions include increasing the water temperature, turning on or off the water
softener, adding an interim rinse, and setting the dishwasher width (18" or 24").
1. To access Service Mode 2, close the door and turn the program selector switch
to Stop.
2. Turn the dishwasher off.
3. Press and hold the Start button while turning the dishwasher on. Release the
Start button and immediately press it 2 more times. Flashing Intake/Drain and
Salt lights indicates successful accessing of Service Mode 2.
4. Turn the program selector switch to the appropriate position in Table 6-10 to
access the various functions of Service Mode 2.
Program selector
switch position
1 o'clock
2 o'clock
4 o'clock
5 o'clock
6 o'clock
7 o'clock
8 o'clock
9 o'clock
10 o'clock

Table 6-10: G 848 Service Mode 2 Functions

6.8.2.3.1

Accessing Fault Codes

1. Access Service Mode 2.
2. Turn the program selector switch to the 1 o'clock position.
3. Press the Start button once.
4. If the Start light is lit, no fault has been stored. If the light is not lit, turn the selector switch
slowly clockwise until the Start light lights up.
5. Use the fault chart (Table 6-11) to determine which fault has been stored in the
dishwasher.
6. Turn the dishwasher off.
Selector switch position
1 o'clock
2 o'clock
3 o'clock
4 o'clock
Function
Fault codes
Program index
EGS
Increase temperature
Water softener
Increase water intake
2 interim rinses
Extended drying fan
time
Dishwasher width
Fault code
Fault
F00
No error
F01
NTC or NTC connections open-circuited
F02
NTC or NTC connections short-circuited
Electronic failure, selector switch position not
F03
found
88
Options
Start light status
See Table 6-11
Flashing
See Table 6-12
Flashing
On
On
Off
Off
150°F
Off
160°F
On
With
Off
Without
On
On
On
Off
Off
Without
Off
With
On
Off
Off
On
On
24"
Off
18"
On
G 600/G 800