Starting The Test Program, Program Start With Reactivation; Service Mode 2; Fault Code Display And Deletion; Table 6-23: G 680, G 880 Service Mode 2 Functions - Miele G 600 Series Technical Information

(all us models)
Hide thumbs Also See for G 600 Series:
Table of Contents

Advertisement

Technical Information
6.8.4.2.1

Starting the Test Program, Program Start with Reactivation

1. Enter Service Mode 1.
2. Turn the program selector switch to the 11 o'clock position. The test program starts
automatically (for the program sequence, see the switching plan).
3. After a test program interruption or after the end of the test program, the selected
program may start with reactivation before the pre-wash. This will be indicated by a lit
Softener LED.
6.8.4.3

Service Mode 2

1. Switch off the appliance, close the door and turn the program selector to Stop.
2. Press and hold the Top solo button while switching the appliance on with the
on/off switch.
3. Release the Top solo button within 1 second, then press and release the Top
solo button twice.
4. The On LED lights up and the Softener and Wash LEDs flash (if this is not the
case, repeat Steps 1 through 3).
5. Turn the program selector switch to the desired setting in accordance with Table
6-23.
6. To save the option: Turn the program selector switch to Stop and switch the
appliance off.
Program selector switch
position (o'clock)
1
2
4
5
6
7
8

Table 6-23: G 680, G 880 Service Mode 2 Functions

1
Standard setting
6.8.4.3.1

Fault Code Display and Deletion

1. Access Service Mode 2.
2. Turn the program selector switch to the 1 o'clock position. The Top solo LED flashes.
3. Press the Top solo button. The Top solo LED lights up when the selector switch is
turned to the position where a fault is registered. Refer to Table 6-24.
4. Turn the program selector switch to Stop and switch the appliance off to delete the fault
code.
Programmable
Function
options
Fault codes
-
Program index
-
Flow meter
-
150°F
Temperature
increase
160°F
With
Softener
Without
24"
Appliance width
(water intake)
18"
Normal
Water quantity
(EPLZ 520 only)
Increased
96
G 600/G 800
Top solo LED
Flashes
Flashes
Flashes
1
Off
On
1
Off
On
Off
On
1
Off
On

Advertisement