Technical Information
6. If the dishwasher door is opened and closed or the dishwasher is turned off and
on, the service mode will be canceled and the machine will continue to advance
normally.
6.8.5.2.1

Test Program

The test program is a program that allows the technician to check all of the major functions of
the dishwasher.
1. Access Service Mode 1.
2. Turn the program selector switch to the 11 o'clock position and press the Start button.
The test program will start and advance automatically.
3. Pressing the Start button repeatedly will allow the technician to advance through the
program. If the Start button is not pressed, the program will run automatically.
6.8.5.3

Service Mode 2

Service Mode 2 is used to determine which upper electronic is in the machine, to
change certain programmed functions and to access fault codes. The programmed
functions include setting the flow meter, increasing the water temperature, turning on
or off the water softener, increasing the water level, extending the circulation fan
time, adding an interim rinse, and setting the dishwasher width (18" or 24").
1. To access Service Mode 2, close the door and turn the selector switch to Stop.
2. Turn the dishwasher off.
3. Press and hold the Top solo and Start buttons while turning the dishwasher on.
A dot (.) in the display and a flashing Intake/Drain light indicates successful
accessing of Service Mode 2.
4. Turn the program selector switch to the appropriate position in Table 6-28 to
access the various functions of Service Mode 2.
5. To save: Press the Top solo button twice, turn the program selector switch to
Stop and turn the dishwasher off.
Selector switch
position (o'clock)
1
2
3
4
5
6
7
8
9

Table 6-28: G 681, G 881 Novo Stella, G 886 Novo Stella Plus Service Mode 2 Functions

1
Factory setting
2
Can only be extended if "+14 min" is selected in programming mode. See Section 6.8.5.1.
Function
Fault codes

Operating hours

Operating hours
Flow meter
Increase temperature
Water softener
Increase water intake
2 interim rinses
Extended drying fan time
100
Options
-
-
-
195 to 205
150°F
160°F
1
With
Without
Without
With
Off
On
Off
2
On
G 600/G 800
Display
F00, F01, etc.
e.g., 007
e.g., 127
195 to 205
50
51
60
61
70
71
80
81
90
91

Advertisement

Table of Contents
loading