G 600/G 800
5. Disconnect the connection plug (Figure 5-27, Item 7).
6. Remove the heater pressure switch. See Section 5.39.
7. Release the hose clips (Figure 5-27, Items 3 and 8).
8. Press the rear casing out slightly to remove the spacer (Figure 5-27, Item 9).
9. Loosen the circulation pump (Figure 5-27, Item 6), and remove it.
10. When re-installing, ensure that the pump seal (Figure 5-27, Item 2) is seated
correctly. Using a small amount of rinse aid may help in getting the seal
positioned correctly. Do not use liquid detergent, as this will cause an
oversudsing condition.

Figure 5-27: Circulation Pump Removal

5.36

Circulation Pump Partition and Impeller Replacement

Warning!
To avoid the risk of leaks, all parts included in the Partition/Impeller Kit should be
installed during this procedure.
1. Remove the circulation pump. See Section 5.35.
2. Remove the 4 screws from the pump housing (Figure 5-28, Item 1).
3. Open the pump housing.
4. Use a large screwdriver to block the motor at the cooling vanes at the rear of the
motor block (Figure 5-28, Item 3). Take care not to damage the motor winding
insulation!
5. Unscrew the impeller (Figure 5-28, Item 2); left-hand thread!
6. Remove the partition (Figure 5-28, Item 4) from the motor block.
7. Install the new partition and impeller.
8. Reassemble the pump housing. Always use a new, unpressed ring.