Gates Opening Wider Than - DoorKing 6050-080 Installation And Owner's Manual

Vehicular swing gate operator
Table of Contents

Advertisement

1.10 Gates Opening Wider Than 90°
The installation of an operator opening gates wider that 90° is the same for 1.3 through 1.8 except the operator and concrete
pad will be in a different position. Individual requirements can be calculated following this 105° demonstrated sample.
Gate
Bracket
28"
Gate bracket
should not be
mounted any
farther from
the hinge than
28" for any
configuration.
24"
Note: Mount operator square to the fence line
and NOT parallel to the open gate.
6050-065-C-2-16
3
Connecting arm's pivot point measurement
62.25" minus (crank arm) 22.25" = 40"
1
An imaginary line drawn from the
closed gate bracket through the
open gate bracket MUST intersect
the operator output shaft. The
crank and connecting arm's pivot
point calculations will be made
from the 2 measurements taken
from this line.
105°
Sample
Standard Cover
36"
Crank arm's pivot point measurement
2
44.5" divided by 2 = 22.25"
5"
Operator
Output Shaft
27"
Distance needed for arm
clearance in the open position.
Arm Assembly
Crank arm's pivot point measurement
in the open position on imaginary line.
Safety cover's installed
measurement for any
configuration.
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6050-0816100-0806100-081

Table of Contents