Summary of Contents for DoorKing 6004

  • Page 1 April 2015 Vehicular Gate Operators Section A1 Vehicular Gate Operators - Reference Guide For current pricing, please use our Dealer Portal. http://doorking.com/dealer-distributor Date Page Comment 4-1-15 April, 2015 reference guide update. Specifications subject to change without notice. Section A1, Page 1...
  • Page 2 Solar Tax Credit Homeowners who purchase a solar powered gate operator manufactured by DoorKing, Inc. after December 31, 2008, may qualify for a 30% Federal Tax Credit off the installed cost of the system. This tax credit is available for the installed cost of the solar powered gate operator on the homeowner’s Federal tax return.
  • Page 3: Table Of Contents

    Vehicular Gate Operators Page Rev 4/1/15 Table of Contents Swing Gate Operators Model 6002 / 6003 ..............................4 Model 6004 / 6400 ..............................5 Model 6050 / 6100 ..............................6 Model 6300 ................................7 Model 6500 ................................8 Model 6524 ................................9 Model 6550 ................................
  • Page 4: Model 6002 / 6003

    Vehicular Gate Operators April, 2015 Page Rev 4/1/15 Models 6002 / 6003 24 Volt DC Swing Gate Actuators Swing gate actuators are designed to operate vehicular swing gates in residential applications where side room is minimal. These actuators install directly on the swing gate and operate on 24 Volt DC power. Control boxes are designed for both single and dual (bi-parting) gate operation and are powered by 120 VAC or 24 VDC with Solar power input.
  • Page 5: Model 6004 / 6400

    24 Volt DC Swing Gate Operators The DKS Model 6004 mounts directly on the gate column while the DKS 6400 installs in-ground making it virtually invisible. These units operate on 24 Volt DC power. Control boxes are designed for both single and dual (bi-parting) gate operation and are powered by 120 VAC or 24 VDC with Solar power input.
  • Page 6: Model 6050 / 6100

    Vehicular Gate Operators April, 2015 Page Rev 4/1/15 Models 6050 / 6100 Automatic Limit Swing Gate Operators These operators can be installed on mounting posts or directly onto a concrete mounting-pad. When ordering, choose both an operator AND an operator mounting kit. Secondary operators are used in bi-parting (dual) gate applications and are commanded from and powered from the primary operator.
  • Page 7: Model 6300

    April 2015 Vehicular Gate Operators Page Rev 4/1/15 Model 6300 Automatic Limit Swing Gate Operators Designed to operate large vehicular swing gates in residential, commercial and industrial applications. These operators can be installed on mounting posts or directly onto a concrete mounting-pad – select mounting kit when ordering. Secondary operators are used in bi-parting (dual) gate applications and cannot be used as a stand-alone device.
  • Page 8: Model 6500

    Vehicular Gate Operators April, 2015 Page Rev 4/1/15 Model 6500 Adjustable Limit Swing Gate Operators Designed to operate large vehicular swing gates in residential, commercial and industrial applications. Secondary operators are used in bi-parting (dual) gate applications cannot be used as a stand-alone device. Operators 6500-080 1/2 HP, 115V (5.4A) Primary 6500-081 1/2 HP, Secondary...
  • Page 9: Model 6524

    April 2015 Vehicular Gate Operators Page Rev 4/1/15 Model 6524 Adjustable Limit DC Swing Gate Operator The model 6024’s main power source is 115 or 230 Volt (switch selectable) single-phase AC power. The operational voltage of the operator is 24 Volt DC and includes built-in battery backup (7.5 AH battery x 2) that provides continued gate operation if the main source power is lost.
  • Page 10: Model 6550

    Vehicular Gate Operators April, 2015 Page Rev 4/1/15 Model 6550 Adjustable Limit Swing Gate Operators Designed to operate very large vehicular swing gates in commercial and industrial applications. Secondary operators are used in bi-parting (dual) gate applications cannot be used as a stand-alone device. Operators 6550-080 1 HP, 115V (9.7A) Primary 6550-084 1 HP, Secondary...
  • Page 11: Swing Gate Accessories

    April 2015 Vehicular Gate Operators Page Rev 4/1/15 Swing Gate Accessories Hinges, Torsion Rod Counter-Balance The DKS Swing Gate Hinges are designed for heavy wrought iron gates. When using the flange style hinge, two are used at the extreme top and bottom of the gate. When using the standard style hinge, the hinge can be welded to a gate mounting post at almost any position and to the gate itself.
  • Page 12: Swing Gate Operator Parts & Accessories

    Circuit Boards Base Plate, Mounting Pipes, Pivot Arm 4302-010 2600-664 Concrete Base Plate Used in models 6002, 6003, 6004 and 6400 Use to mount the 6050 or 6100 post mount operators onto an existing concrete pad 4405-010 2600-260 Mounting Pipe Used in model 6500, 6550 Use with 6050 and 6100 post mount operators.
  • Page 13 April 2015 Vehicular Gate Operators Page Rev 4/1/15 Blank Page Specifications subject to change without notice. Section A1, Page 13...
  • Page 14: Model 9050 / 9100

    Vehicular Gate Operators April, 2015 Page Rev 4/1/15 Models 9050 / 9100 Automatic Limit Slide Gate Operators The model 9050 is designed for limited-duty residential applications only. The model 9100 is designed for continuous-duty residential and commercial applications and has a full feature circuit board. 20-feet of #40 chain is included with these operators.
  • Page 15: Model 9150

    April 2015 Vehicular Gate Operators Page Rev 4/1/15 Model 9150 Automatic Limit Slide Gate Operators The model 9150 slide gate operator is designed to operate vehicular sliding gates in residential commercial and industrial applications. The operator has a full feature circuit board and includes 20-feet of #40 chain. Operators 9150-084 1/2 HP, 115V (5.4A) 9150-086 1/2 HP, 115V (5.4A) w/C.O.
  • Page 16: Model 9000

    Vehicular Gate Operators April, 2015 Page Rev 4/1/15 Model 9000 Adjustable Limit Slide Gate Operators The model 9000 slide gate operator is designed to operate vehicular sliding gates in residential commercial and industrial applications. The operator has a full feature circuit board and includes 20-feet of #40 chain. Secondary operators are used in bi-parting (dual) gate applications and are commanded from and powered from the primary operator.
  • Page 17: Model 9024

    April 2015 Vehicular Gate Operators Page Rev 4/1/15 Model 9024 Adjustable Limit DC Slide Gate Operator The model 9024’s main power source is 115 or 230 Volt (switch selectable) single-phase AC power. The operational voltage of the operator is 24 Volt DC and includes built-in battery backup (7.5 AH battery x 2) that provides continued gate operation if the main source power is lost.
  • Page 18: Slide Gate V-Wheels

    Vehicular Gate Operators April, 2015 Page Rev 4/1/15 Slide Gate Accessories V-Wheels DKS V-wheels are used in slide gate applications that utilize an inverted “V” type track. V-Wheel assemblies are designed for 2 inch gate frames and tandem assemblies can be used on any size frame. Replacement V-Wheels 1201-004 •...
  • Page 19: Slide Gate Guide Rollers & Accessories

    April 2015 Vehicular Gate Operators Page Rev 4/1/15 Slide Gate Accessories Guide Rollers, Chain Idler, End Catch Guide rollers are guarded to meet current industry safety standards. The DKS chain idler assembly is used when slide gate operators are rear-mounted. The end retainer provides a guide for slide gates to slip into, and has a cap that prevents the gate from being lifted off the track when it is in the full closed position.
  • Page 20: Slide Gate Operator Parts & Accessories

    Vehicular Gate Operators April, 2015 Page Rev 4/1/15 Slide Gate Operator Parts & Accessories Miscellaneous Parts & Accessories Circuit Boards Chain 4402-009 2600-443 Nickel Plated #41 Chain – 10 Ft Used in model 9300 1 HP only 2600-444 Nickel Plated #40 Chain – 10 Ft 4402-010 2600-475 Stainless Steel #41 Chain –...
  • Page 21 April 2015 Vehicular Gate Operators Page Rev 4/1/15 Blank Page Specifications subject to change without notice. Section A1, Page 21...
  • Page 22: Entrapment Protection Devices Type B1 And B2

    Vehicular Gate Operators April, 2015 Page Rev 4/1/15 Entrapment Prevention Devices Type B1 and Type B2 Entrapment prevention devices are required in almost all general access automated gate applications. Photo-cells are used as type B1 (non-contact sensors) devices. Electric edges are used as type B2 (contact sensors) devices. Type B1 Non-Contact Sensors 8080-010 Infrared Thru-Beam (Do not use with 9200 and 9500 series operators)
  • Page 23: Loop Detectors And Loops

    April 2015 Vehicular Gate Operators Page Rev 4/1/15 Vehicle Protection Loop Detectors and Loops Loop detectors and loops are strongly recommended on all automated vehicular gate applications to help prevent gates from closing on vehicles in the path of the gate. Plug-in Loop Detectors –...
  • Page 24: Gate Operator Control Stations

    Vehicular Gate Operators April, 2015 Page Rev 4/1/15 Control Stations Manual Control Gate operator control stations provide complete manual control for DKS vehicular gate operators. The unique logic inputs found on DKS gate operators require only 3 wires for connection to a 3-button control station. 1200-007 •...
  • Page 25: Postal And Fire Department Lock Boxes

    April 2015 Vehicular Gate Operators Page Rev 4/1/15 Lock Boxes Postal and Fire Department Postal and Fire Department lock boxes provide a method for these authorities to gain access through a vehicular access gate. 1402-080 5.00 2.38 • Accepts standard postal key lock •...
  • Page 26: Time Clocks, Surge Suppressers, Traffic Signal

    Vehicular Gate Operators April, 2015 Page Rev 4/1/15 Accessories Time Clock & Surge Suppressers Electronic time clocks are ideal for use in applications where an access control system does not control “hold open” time periods. Vehicular gate operators and barrier gate operator systems are typical. Surge suppressers are designed to provide additional protection to equipment in areas prone to voltage spikes and surges.
  • Page 27: Accessory Transformers

    April 2015 Vehicular Gate Operators Page Rev 4/1/15 Accessory Transformers 12, 16, 24 Volt AC & DC Transformers A variety of accessory transformers are available to power the different products that we sell. AC transformers are typically used with access control devices and controllers, while DC transformers are used with magnetic locks and proximity card readers.
  • Page 28: Model 1000

    • Includes two (2) batteries and will power two (2) 1/2 HP operators or one (1) 1 HP operator • Suitable for use with all DoorKing and non-DoorKing Model 1000 brand gate operators 1000-045 Post Mount for 1000 Inverter 1000-048 Battery & Cable Assembly •...