Page 1
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE/DOOR SYSTEMS TECHNICIAN ONLY. Visit www.doorking.com/dealer-locator to find a professional installing and servicing dealer in your area. Installer: Leave manual with property owner. Date Installed:...
QUICK GUIDE: DIP-Switches See page 21 & 22 for more info about DIP-switches. Every time the operator is powered up, the First open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions (See page 23). Whenever a switch setting is changed, power MUST be cycled to the operator.
(Single channel) for a single operator. Terminal #10 connected to terminal #4 will FULLY open Dry Relay Contact bi-parting gates. Dual operators ONLY using DoorKing’s plug-in DUAL channel loop detector. (Page 34). Dry Relay Contact Operation of relay is dependent on setting of SW 1, switches 4 and 5.
Page 4
4” Minimum DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved.
Install a contact sensor in this area for safety. (See on next page and page 26). DoorKing recommends installing screened wire mesh on the ENTIRE gate AND and on that portion of the adjacent fence that the gate covers in the open position. (See above).
Illustration not to scale. Safety Information for Slide Gate Operators Entrapment protection devices are required to reduce the risk of injury. Physical Stops Install sensors where the risk of entrapment or obstruction exists while Positive stops shall be required gate is moving. Individual requirements will vary. See pages 25-29 for to limit travel to the designed more information on typical layout locations and setup.
ASTM F2200 Standard for Gate Construction Vehicular gates should be constructed and installed in accordance with ASTM F2200; Standard Specification for Automated Vehicular Gate Construction. For a copy of this standard, contact ASTM directly at 610-832-9585; service@astm.org; or www.astm.org. Important Safety Instructions WARNING - To reduce the risk of injury or death: 1.
Important Notices Vehicular gate operator products provide convenience and security. However, gate operators must use high levels of force to move gates and most people underestimate the power of these systems and do not realize the potential hazards associated with an incorrectly designed or installed system. These hazards may include: •...
UL 325 Entrapment Protection UL 325 Classifications Authoriz ed Personn el ONLY Class I - Residential Class III - Industrial/Limited Access Vehicular Gate Operator Vehicular Gate Operator A vehicular gate operator (or system) intended for use in garages A vehicular gate operator (or system) intended for use in an or parking areas associated with a residence of one-to four single industrial location or building such as a factory or loading dock families.
Glossary GATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area.
1.1 Hardware for the Gate Good hardware is essential for proper operation of a sliding gate. DoorKing has a full line of gate hardware products that will ensure safe, reliable and long lasting gate operation. The gate must be properly installed and roll smoothly in both directions.
CLASS VEHICUL C22.2 GATE 53382 MODEL SERIAL OPERATO a i n VOLTS AMPS GATE DoorKing, LOAD PHASE Inc., Inglewood, g e s n t a s u g s h o e t y r a y s a f...
(Both are shown, only one type is needed). Additional hardware required. Post base plate (P/N 2600-495) 6 x 6 steel posts not available from DoorKing. Base plate stop brackets (P/N 2600-970) bolts on post base plate when using chain stops.
Page 15
Rear Position with Post Mount Hides the chain from outside the property looking in. • Chain setup is the same as above. Additional hardware required. Post base plate (P/N 2600-495) 6 x 6 steel posts not available from DoorKing. 9150-065-Y-12-20...
Page 16
Chain Idler Wheels Additional hardware required. Post base plate (P/N 2600-495) 6 x 6 steel posts not available from DoorKing. Endless idler assembly (P/N 2600-818). Additional chain #40 (P/N 2600-442 - 20 ft. per box). Gate end retainer (P/N 1204-004).
Use only sweeps for conduit bends. Do not use 90° elbows as this will make wire pulls very Elbow difficult and can cause damage to wire insulation. DoorKing recommends using 3/4-inch conduit. • Installation of External Entrapment Protection Devices are REQUIRED (photo sensors and/or reversing edges).
VEHICULAR GATE OPERATOR same conduit. CLASS MODEL SERIAL VOLTS PHASE AMPS 60 Hz Operator MUST MAX GATE LOAD DoorKing, Inc., Inglewood, CA Fail Secure be level. Key Lock High Volt High Volt Volt Volt Note: Operator must be mounted Conduit Knock-Out Sizes Pad, post or 1”...
Attaching Operator Connect Chain Bracket to Concrete t i o to Gate. Weld completely DoorKing recommends a around bracket. Chain nut minimum of four (4) 3/8” x 2” Chain and chain bolt MUST NOT sleeve anchors (not supplied). protrude past gate frame.
Endless Idler Assembly (On Select Installations) DoorKing offers an endless idler assembly with a protective cover designed for the Model 9150 installations (P/N 2600-818). Make sure the endless idler assembly is securely fastened to the wall or post (Depending on which type of installation will be used).
Installing the Chain Tray Kit A chain tray is recommended for gates longer than 20 ft. to support the weight of the chain. DoorKing offers a chain tray kit in sections to fit any length gate. (DoorKing P/N 2601-270 10 Ft. section)
SECTION 2 - AC POWER TO OPERATOR(S) Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a licensed electrical contractor perform this work.
2.2 High Voltage Terminal Connection • Route incoming AC power wire through the high voltage conduit and run wire in the operator as shown. • Be sure wiring is installed in accordance with local codes. Be sure to color code all wiring. •...
ONLY. It will use the ENABLE STOP Power LED SHORT PINS 1&2 Auto-Close timer when turned ON. 3-Button Control Station Jumper Page 32 Fire Dept Open DOORKING UL 325 4602-018 Connect ONLY emergency access DIP-Switches Pages 25-29 controls accessible by authorized UL 325 personnel (e.g., fire, police, EMS).
3.2 DIP-Switch SW 1 and SW 2 Settings The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then turned back on for the new setting to take affect.
Page 26
7-ON 8-ON Switch 1 Determines if the output of the loop detector (DoorKing loop detectors only) plugged into the EXIT loop SW 2 Switch 1 port will be sent directly to the microprocessor to open (or reverse a closing gate) the gate, or if the output is directed to Main Terminal #10 where it can be connected to other input terminals.
3.3 Automatic Open / Close Limit Adjustment The 9150’s open/close limits DO NOT have to be physically adjusted. Every time the 9150 is powered up, the first open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions. These positions are determined by the physical stops that have been installed (See section 1.2, page 10).
3.4 Clutch Adjustment In addition to the inherent reverse sensor, this operator is equipped with a mechanical slip clutch to further reduce the possibility of injury should an entrapment occur. DO NOT over tighten the clutch to compensate for a gate that is damaged, poorly constructed or too heavy. Over tightening the clutch would create a hazard which could result in serious injury or death to persons who may become entrapped.
ENABLE STOP ENABLE STOP SHORT PINS 1&2 SHORT PINS 1&2 terminal. 4 - CLOSE Edge RE VE LO OP DOORKING M OV 4602-018 S IN 1 - OPEN Beam (Switch 1) e of e on t allo e are...
4.2 Entrapment Protection Device Locations Typical Photo Sensor mounting height If the distance between the gate and distance away from gate. and wall is greater than 2 1/4”. Filler Post or Barrier Secure Side Non-Secure Side Inside Property Outside Property 5”...
Page 31
Wireless Reverse Edge Sample Setup - Single Receiver Type of wiring to be used on ALL external devices: A) Type CL2, CL2P, CL2R, or CL2X. B) Other cable with equivalent or better electrical, mechanical, and flammability ratings. P/N - 8080-008 RF Monitored Gate Link Kit (RB-G-K10) Miller Edge Sensing Edges - All models with a T2 (resistive) termination.
4.4 Wide Gate Photocell Device Locations Sample A wide gate will not be protected from obstructions using only one photocell in each cycling direction. DoorKing suggests using photocells on BOTH sides of a wide gate in the opening AND closing direction to better protect against obstructions during gate cycling. A MIM-62 (sold separately) is needed to wire this type of setup (see below).
A loop detection system will sense a vehicle like a metal detector and send a signal to the gate operator preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. DoorKing recommends that a licensed installer perform this work.
(Single channel) for a single operator. Terminal #10 connected to terminal #4 will FULLY open Dry Relay Contact bi-parting gates. Dual operators ONLY using DoorKing’s plug-in DUAL channel loop detector. (Page 34). Dry Relay Contact Operation of relay is dependent on setting of SW 1, switches 4 and 5.
Station Jumper will also open the gate to the partial open setting. Open OFF. If the Inherent Reverse Sensor gets activated Telephone during the close cycle, it will always fully open DOORKING Entry Close SW 2 the gate. 4602-018 IMPORTANT:...
DOORKING 4602-018 Gate Tracker (Quad Box Shown) DoorKing Access Control System (Model 1833, 1835, 1837 or 1838) tracker system can be connected.This system can keep track of gate operator cycle count, shorted inputs, loop detector problems, any forced entry attempts, if the gate has struck anything during the open or close cycle, power interruptions, etc.
Orange REVERSE Exit Loop SENSITIVITY Main Terminal Main Terminal Interconnection Cable Sold separately from DoorKing. UL 325 Terminal Close Beam Red #3 #3 Red Close Beam Type of wiring to be used on ALL Common Gray #4 #4 Gray Common...
SECTION 6 - OPERATING INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3.
6.2 Shutdown Conditions Under various entrapment conditions the operator will assume either a soft or hard (alarm) shutdown. To determine what type of reset action is required, you will need to understand how the different entrapment conditions affect the gate operator.
“chirp every 5 sec.” and the hard shutdown condition will remain in affect until the reset button is pushed. Note: DoorKing operators have a built-in alarm reset push button mounted on the operator above the power ON-OFF toggle switch. Activating this button will return the gate operator to normal operation, but will not cycle the gate operator.
Page 42
Fail-Secure Manual Release System (Owner Installed) This manual release system (Installed 2600-865 Fail-Secure Manual Release Kit) allows the gate to be manually operated ONLY after unlocking the gate operator. Power outages or turning power off WILL NOT allow gate to be manually operated without physically unlocking the gate operator with the key first.
Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or suspected. High cycle usage may require more frequent service checks. Contact servicing dealer. If you don’t know your servicing dealer, see DoorKing’s “DEALER LOCATOR” at www.DoorKing.com t c h...
For more information on trouble shooting loops and loop detectors, refer to your loop detector instruction sheet and to the DoorKing Loop and Loop Detector Information Manual. 4. Check to be sure that there are no shorted or open control wires from the keying devices to the gate operator. If a keying device fails to open the gate, press the Key Switch or momentarily jumper across terminals 4 and 18 on the operator circuit board.
Page 45
Symptom Possible Solution Operator will not run, entrapment protection • The entrapment protection device has a fault or the wiring to it is shorted. input(s) LED is ON. Operator will not run, entrapment protection • The entrapment protection device is not connected or the wiring to it is open. input(s) LED is Blinking.
UL 325 Monitored Entrapment Protection Devices available for model 9150 slide gate operator. Type B2 Contact Sensors (Reversing Edge) DoorKing 8080 Series Sensing Edges Miller Edge Sensing Edges - all models with a T2 (resistive) termination. Miller Edge wireless monitored transmitter/receiver kit model RB-G-K10...
Reset Button Neutral Power AC Power Switch Convenience Outlets REVERSE LOOP EXIT LOOP FULL OPEN OPEN Board TIMER Ground Green ENABLE STOP SHORT PINS 1&2 Green Blue DOORKING 4602-018 White Black Blue Brown REVERSE SENSITIVITY White Loop White Yellow 9150-065-Y-12-20...
Page 48
Button Neutral Power AC Power Switch Convenience Outlets REVERSE LOOP EXIT LOOP FULL OPEN OPEN Board TIMER Ground Green ENABLE STOP SHORT PINS 1&2 Green Orange DOORKING Yellow 4602-018 White Black Blue Brown REVERSE SENSITIVITY White Loop White Yellow 9150-065-Y-12-20...
SECTION 8 - OWNER OF THE GATE OPERATOR 8.1 Alarm Sounding OR “Chirping” and Gate WILL NOT Operate Operator is in a HARD Shutdown Condition: The alarm will sound for (5) five minutes. After five minutes the alarm will start “Chirping” every 5 seconds and continue “Chirping” until operator gets reset. A KEY has been supplied that will Note: The owner of the gate unlock the power switch cover on...
8.2 Manual Gate Operation Caution: NEVER attempt to manually operate the gate until you have VERIFIED that power to the gate operator has been SHUT-OFF! Please read SECTION 6 - OPERATING INSTRUCTIONS for more information about operating this gate operator. Factory Equipped FAIL-SAFE Manual Operation Gate can be IMMEDIATELY manually operated (pushed open) during a power outage.
If you feel uncomfortable performing any of these inspections or testing, a qualified service technician will perform the visual inspections and testing for you. You can find a trained service technician at DoorKing’s “Dealer Locator” at www.doorking.com Visual Inspection Visually inspect the rollers, fasteners, brackets and other gate hardware for proper alignment, proper tightness, and signs of damage, breakage, looseness, rust or wear.
8.4 New Installation Checklist for Installer and Property Owner ✓ Instructions: Check the space next to each item (“ ”) to indicate that it has been addressed by installer AND property owner. If it is not applicable, enter N/A. Please note that the checklist is intended to be a summary of many important automated vehicular gate aspects, But may not inclusively identify all potential hazards of every specific gate system installation.
Page 54
NOT run without one or more monitored type B1 or B2 entrapment protection devices in EACH direction of gate travel. UL 325 August 2018 Standard THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE/DOOR SYSTEMS TECHNICIAN ONLY. Visit www.doorking.com/dealer-locator to find a professional installing and servicing dealer in your area. www.doorking.com DoorKing, Inc.