DoorKing 4302 Mounting Instructions

Gate operator and control box options
Hide thumbs Also See for 4302:

Advertisement

Quick Links

Gate Operator Mounting and
4302 Control Box Options
Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists. The operator
will NOT run without one or more monitored type B1 or B2 entrapment protection devices in EACH entrapment area.
UL 325 August 2018 Standard
To wire this operator and complete the installation,
please refer to YOUR CHOSEN 4302 control box
"Wiring/Owner's manual":
4302 115 VAC control boxes manual - 4302-065
OR
4302 Solar control box manual - 4302-067
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE/DOOR SYSTEMS TECHNICIAN ONLY.
Visit www.doorking.com/dealer-locator to find a professional installing and servicing dealer in your area.
Installer: Leave manual with property owner.
Date Installed:
Installer/Company Name:
Phone Number:
Conforms To UL STD 325
Certified To CSA STD C22.2 # 247
Vehicular Swing Gate Operator
Circuit Board
Serial Number
and Revision Letter:
Copyright 2021 DoorKing
®
, Inc. All rights reserved.
6004
6004
6004
6004-065-X-2-21
D O O R K I N G
D
O
O
R
K
I
N
G

Advertisement

Table of Contents
loading

Summary of Contents for DoorKing 4302

  • Page 1 4302 Solar control box manual - 4302-067 THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE/DOOR SYSTEMS TECHNICIAN ONLY. Visit www.doorking.com/dealer-locator to find a professional installing and servicing dealer in your area. Installer: Leave manual with property owner.
  • Page 3: Table Of Contents

    Mounting Bracket and Gate Attachment Bracket Operator Layouts “Gate Opens to the Inside” or “Gate Opens to the Outside” 4302 Control Box Options 13-14 For installers familiar with DoorKing products (Limit Sensors Adjustment) Install Warning Signs In-Ground Loops Entrapment Protection Locations...
  • Page 4: 6004 Specifications

    Left Side Position DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved.
  • Page 5: Swing Gate Requirements

    Swing Gate Requirements This operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. For pedestrian access in the vicinity of an automated vehicular gate, separate pedestrian access shall be provided or available.
  • Page 6 Swing Gate Requirements Continued Monitored Non-contact CLOSING Sensor (Type B1) Minimizes the potential of the gate closing on vehicular or other traffic that loops cannot sense. Monitored device helps protect against entrapment Reverse Loop when needed. Minimizes the potential of the gate closing when a vehicle is present.
  • Page 7: Astm F2200 Standard For Gate Construction

    ASTM F2200 Standard for Gate Construction Vehicular gates should be constructed and installed in accordance with ASTM F2200; Standard Specification for Automated Vehicular Gate Construction. For a copy of this standard, contact ASTM directly at 610-832-9585; service@astm.org; or www.astm.org. Important Safety Instructions WARNING - To reduce the risk of injury or death: 1.
  • Page 8: Important Notices

    Important Notices Vehicular gate operator products provide convenience and security. However, gate operators must use high levels of force to move gates and most people underestimate the power of these systems and do not realize the potential hazards associated with an incorrectly designed or installed system. These hazards may include: •...
  • Page 9: Ul 325 Entrapment Protection

    UL 325 Entrapment Protection UL 325 Classifications Authoriz ed Personn el ONLY Class I - Residential Class III - Industrial/Limited Access Vehicular Gate Operator Vehicular Gate Operator A vehicular gate operator (or system) intended for use in garages A vehicular gate operator (or system) intended for use in an or parking areas associated with a residence of one-to four single industrial location or building such as a factory or loading dock families.
  • Page 10: Glossary

    Glossary GATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area.
  • Page 11: Installation

    INSTALLATION Prior to beginning the installation of the swing gate operator, we suggest that you become familiar with the instructions and illustrations in this manual. This will help insure that your installation is performed in an efficient and professional manner compliant with UL 325 safety and ASTM F2200 construction standards. The proper installation of the vehicular slide gate operator is an extremely important and integral part of the Check all local building ordinances and building codes prior to installing overall access control system.
  • Page 12: Operator Description And Disassembly

    Operator Description and Disassembly Left-Side Orientation Right-Side Orientation r u - Remove cover and 2 thru-bolts to remove mounting bracket. l o c v e r Note: Electronic pallet can be removed from the motor The mounting bracket and motor can be flipped for by disconnecting right-side opening position (Electronic pallet not shown).
  • Page 13: Operator Mounting Positions

    Operator Mounting Positions D O O R K I N G Support Bar Middle D O O R K I N G A support bar must be used if the operator is mounted Bottom Installation Note: Make sure that the in the middle of the gate and typically spans 4 or 5 operator is mounted high enough off the pickets.
  • Page 14: Operator Layouts "Gate Opens To The Inside" Or "Gate Opens To The Outside

    Operator Layouts Top view of operator with mounting bracket installed. ” Calculate dimension for your specific installation first. That will determine dimension limitations depending on which gate opening direction you select (See tables below). Use to help calculate dimension Gate Opens to the Inside Opens to the Inside - Inches Closed Gate C max.
  • Page 15: 4302 Control Box Options

    4302 115 VAC Control Boxes 115 VAC Control Boxes properly grounded. See the 4302 115 VAC control boxes Wiring/Owner’s manual for more information about mounting and PRIMARY Operator wiring to control box. D O O R K I N G...
  • Page 16 4302 Solar Control Box Coaxial Cable Solar Panel Antenna Kit P/N 2000-076 P/N 1514-073 See the 4302 solar control box Wiring/Owner’s (Sold separately) manual for more information about concerns, Mounting Pole considerations and recommendations for proper Not Provided solar panel positioning, mounting and wiring to control box.
  • Page 17: For Installers Familiar With Doorking Products (Limit Sensors Adjustment)

    Limit Sensors Adjustment This guide is for installers familiar with DoorKing products ONLY. DO NOT use this as your only source to wire, adjust limit sensors and DIP-switches if you are unfamiliar with this operator. Please refer to the control box manual you are installing for complete wiring, adjustments and DIP-switch settings for this operator.
  • Page 18: Install Warning Signs

    Install Warning Signs This DoorKing Swing Gate Operator is shipped with two warning signs. The purpose of the warning sign is to alert uninformed persons, and to remind persons familiar with the gate system, that a possible hazard exists so that appropriate action can be taken to avoid the hazard or to reduce exposure to the hazard.
  • Page 19: Entrapment Protection Locations

    Entrapment Protection Locations External Entrapment Protection Devices: In addition to the inherent reversing sensor system, this operator has a UL 325 terminal for the connection of photo sensors-Type B1 and/or reversing edges-Type B2 entrapment protection required by UL 325 standards. Install these devices where the risk of entrapment or a safety hazard exists.
  • Page 20 Entrapment Protection Locations Continued A monitored reversing edge (Type B2) or a monitored photo sensor (Type B1, see previous page) MUST be installed in EACH entrapment area or operator WILL NOT function. Monitored Edge Transmitter OPTIONAL wireless transmitter can be used. Receiver MUST monitor for the presence of the transmitter.
  • Page 21: Accessory Items

    P/N 4302-112 - 115 VAC Deluxe Control Box, 115 VAC 60 Hz Input to box, 24 VDC output to gate operator. 3-115 VAC convenience outlets. P/N 4302-114 - 18 ah Solar Control Box, 24 VDC 20 Watt Input to box, 24 VDC output to gate operator. 2 - 12 Volt 18 Amp Hr batteries.
  • Page 22: 6004 Primary/Secondary 4302 Circuit Board Connection

    6004 Primary/Secondary 4302 Circuit Board Connection Primary Operator Secondary Operator D O O R K I N G D O O R K I N G Operator Cable Operator Cable Brown 1 Blue 2 Orange 3 Red 4 Yellow 5...
  • Page 23 6004-065-X-2-21...
  • Page 24 NOT run without one or more monitored type B1 or B2 entrapment protection devices in EACH entrapment area. UL 325 August 2018 Standard THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE/DOOR SYSTEMS TECHNICIAN ONLY. Visit www.doorking.com/dealer-locator to find a professional installing and servicing dealer in your area. www.doorking.com DoorKing, Inc.

This manual is also suitable for:

60046004-3804302-0104302-0124302-018

Table of Contents