1.3 Underground Conduit Requirements

Primary
Operator
Position
DoorKing's Primary/Secondary Interconnection Cable (Dual Operator Application Only)
External Safety Devices, Controls and P.A.M.S. Wires (Low Voltage wire insulation)
Loop Lead-In Wires (Low Voltage wire insulation)
AC Input Power (High Voltage wire insulation)
Sweeps
The conduit requirements are for a typical slide gate operator installation (the secondary operator is shown for those
applications where a secondary operator may be used). The conduit requirements for your application may vary from this
depending on your specific needs.
Use only sweeps for conduit bends. Do not use 90° elbows as this will make wire pulls very difficult
and can cause damage to wire insulation. DoorKing recommends using 3/4-inch conduit.
• Installation of External Entrapment Protection Devices is REQUIRED (photo sensor and/or reversing edge).
Be sure that all conduits are installed in accordance with local codes.
Never run low voltage rated wire insulation in the same conduit as high voltage rated wire insulation.

1.4 Pad Mount

Secure the operator to the
concrete pad with four (4)
3/8
3/8" x 3" sleeve anchors
(not supplied).
Operator MUST
be level.
Note: Right support leg removed from
this illustration to show conduit detail.
Low
High
Volt
Volt
10
(Secondary Operator AC Power and Communication wires)
Note: 2" thick
gate Illustrated.
Arm
5"
Rotation
Area
11"
9.5" 6"
Depth of the concrete pad is
determined by soil conditions and
local building codes. Reinforced
concrete recommended.
90°
Gate Bracket Height
Secondary
Operator
Position
Concrete Pad
Sweep
YES
Elbow
NO
2.5"
3"
Pad Support Base
Left Support Leg
Conduit
10"
14"
Right Support Leg
2.5"
Concrete Pad
Concrete Pad Position
Note: If allowed by local codes, the
top of the concrete pad can be flush
with ground level, which will allow
the gate bracket to be mounted
lower on the gate.
Open Gate
3"
Output
22"
Shaft
6050-065-C-2-16