DoorKing 9150-084 Installation & Owner's Manual

DoorKing 9150-084 Installation & Owner's Manual

9150 series vehicular slide gate operator
Table of Contents

Advertisement

Installation/Owner's Manual
Use this manual for circuit board 4602-010 Revision AA or higher.
Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists.
The operator will not run without one or more monitored type B1 or B2 entrapment protection devices.
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY.
Visit www.dkslocator.com to find a professional installing and servicing dealer in your area.
Date Installed:
Installer/Company Name:
Phone Number:
Leave Manual with Owner
Conforms To UL STD 325
Certified To CSA STD C22.2 # 247
W A
R N
I N
G
M O
V IN
S E
R IO
G
G A
U S
T E
O p
e ra
IN
J U
C A
an
te
d fr
g a
R Y
N
e e
te
C A
o f
o n
D o
ly
O R
U S
p eo
w h
n o
p le
D E
E
o r
t al
en
o p
lo w
an
g a
A T
er at
d o
te
ch
b st
ar e
H
D o
e g
ild
a is
a te
re n
ru
n o
.
c ti
in
p at
t st
to
o n
si g
h w
an
p la
s .
d in
y in
h t
h ile
R ea
g at
g at
g at
d o
e is
e p
e ar
w n
at h
ea
m o
er 's
vi n
o r
g .
w a
m an
lk
th ro
u a
l an
u g
d sa
h
fe ty
in st
ru
ct io
n s.
C O
N F
A N
O R
S I/
M S
U L
T O
C A
C E
-3 2
5
N /C
R T
IF IE
S A
C 2
D
V E
T O
H IC
2 .2
U L
N O
C L
. 2
53
A R
38
A S
4 7
2
S
G A
T E
M O
O P
D E
L
E R
A T
S E
H P
O R
R IA
L
V O
L T
S
A M
P S
M A
X G
P H
A S
A T
E L
E
O A
D o
D
6 0
o rK
H z
in g
, In
c .,
In g
le w
o o
d ,
C A
Circuit Board
Serial Number
and Revision Letter:
Copyright 2018 DoorKing, Inc. All rights reserved.
Series 9150
Series 9150
Series 9150
Vehicular Slide Gate Operator
9150-065-M-5-18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9150-084 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DoorKing 9150-084

  • Page 1 Visit www.dkslocator.com to find a professional installing and servicing dealer in your area. Date Installed: Installer/Company Name: Circuit Board Serial Number Phone Number: and Revision Letter: Leave Manual with Owner Copyright 2018 DoorKing, Inc. All rights reserved. Conforms To UL STD 325 Certified To CSA STD C22.2 # 247...
  • Page 2: Quick Guide: Dip-Switches

    QUICK GUIDE: DIP-Switches See page 21 & 22 for more info about DIP-switches. Every time the operator is powered up, the First open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions (See page 23). Whenever a switch setting is changed, power MUST be cycled to the operator.
  • Page 3: Quick Guide: Terminal Descriptions

    (Single channel) for a single operator. Terminal #10 connected to terminal #4 will FULLY open Dry Relay Contact bi-parting gates. Dual operators ONLY using DoorKing’s plug-in DUAL channel loop detector. (Page 32). Dry Relay Contact Operation of relay is dependent on setting of SW 1, switches 4 and 5.
  • Page 4 4” Minimum DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved.
  • Page 5: Table Of Contents

    TABLE OF CONTENTS QUICK GUIDES Quick Guide: DIP-Switches Quick Guide-1 Quick Guide: Terminal Descriptions Quick Guide-2 Operator Specifications Previous Page Slide Gate Requirements Safety Information for Slide Gate Operators ASTM 2200 Standard for Gate Construction Important Safety Instructions Instructions regarding intended installation: Important Notices UL325 Entrapment Protection Glossary...
  • Page 6: Slide Gate Requirements

    (See on next page and page 26). DoorKing recommends installing screened wire mesh on the ENTIRE gate AND and on that portion of the adjacent fence that the gate covers in the open position. (See above).
  • Page 7: Safety Information For Slide Gate Operators

    Illustration not to scale. Safety Information for Slide Gate Operators Entrapment protection devices are required to reduce the risk of injury. Physical Stops Install sensors where the risk of entrapment or obstruction exists while Positive stops shall be required gate is moving. Individual requirements will vary. See pages 25-28 for to limit travel to the designed more information on typical layout locations and setup.
  • Page 8: Astm 2200 Standard For Gate Construction

    ASTM F2200 Standard for Gate Construction Vehicular gates should be constructed and installed in accordance with ASTM F2200; Standard Specification for Automated Vehicular Gate Construction. For a copy of this standard, contact ASTM directly at 610-832-9585; service@astm.org; or www.astm.org. Important Safety Instructions WARNING - To reduce the risk of injury or death: 1.
  • Page 9: Important Notices

    Important Notices Vehicular gate operator products provide convenience and security. However, gate operators must use high levels of force to move gates and most people underestimate the power of these systems and do not realize the potential hazards associated with an incorrectly designed or installed system. These hazards may include: •...
  • Page 10: Ul325 Entrapment Protection

    UL 325 Entrapment Protection UL 325 Classifications Authoriz ed Personn el ONLY Class I - Residential Class III - Industrial/Limited Access Vehicular Gate Operator Vehicular Gate Operator A vehicular gate operator (or system) intended for use in garages A vehicular gate operator (or system) intended for use in an or parking areas associated with a residence of one-to four single industrial location or building such as a factory or loading dock families.
  • Page 11: Glossary

    Glossary GATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area.
  • Page 12: Section 1 - Installation

    1.1 Hardware for the Gate Good hardware is essential for proper operation of a sliding gate. DoorKing has a full line of gate hardware products that will ensure safe, reliable and long lasting gate operation. The gate must be properly installed and roll smoothly in both directions.
  • Page 13: Types Of Gates

    S TO CLASS VEHICUL C22.2 GATE 53382 MODEL SERIAL OPERATO VOLTS AMPS GATE DoorKing, LOAD PHASE Inc., Inglewood, n t a s h o r a y g a t h a i r n a f o r e l O...
  • Page 14: Operator Mounting Positions

    (Both are shown, only one type is needed). Additional hardware required. Post base plate (P/N 2600-495) 6 x 6 steel posts not available from DoorKing. Base plate stop brackets (P/N 2600-970) bolts on post base plate when using chain stops.
  • Page 15 Rear Position with Post Mount Hides the chain from outside the property looking in. • Chain setup is the same as above. Additional hardware required. Post base plate (P/N 2600-495) 6 x 6 steel posts not available from DoorKing. 9150-065-M-5-18...
  • Page 16 Chain Idler Wheels Additional hardware required. Post base plate (P/N 2600-495) 6 x 6 steel posts not available from DoorKing. Endless idler assembly (P/N 2600-818). Additional chain #40 (P/N 2600-442 - 20 ft. per box). Gate end retainer (P/N 1204-004).
  • Page 17: Underground Conduit Requirements

    Use only sweeps for conduit bends. Do not use 90° elbows as this will make wire pulls very Elbow difficult and can cause damage to wire insulation. DoorKing recommends using 3/4-inch conduit. • Installation of External Entrapment Protection Devices are REQUIRED (photo sensors and/or reversing edges).
  • Page 18: Pad, Post Or Ceiling Mount Without/With J-Box Setup

    VEHICULAR GATE OPERATOR same conduit. CLASS MODEL SERIAL VOLTS PHASE AMPS 60 Hz Operator MUST MAX GATE LOAD DoorKing, Inc., Inglewood, CA Fail Secure be level. Key Lock High Volt High Volt Volt Volt Note: Operator must be mounted Conduit Knock-Out Sizes Pad, post or 1”...
  • Page 19: Mounting Operator And Chain

    Attaching Operator Connect Chain Bracket to Concrete t i o to Gate. Weld completely DoorKing recommends a around bracket. Chain nut minimum of four (4) 3/8” x 2” Chain and chain bolt MUST NOT sleeve anchors (not supplied).
  • Page 20: Installation Of Warning Signs

    Endless Idler Assembly (On Select Installations) DoorKing offers an endless idler assembly with a protective cover designed for the Model 9150 installations (P/N 2600-818). Make sure the endless idler assembly is securely fastened to the wall or post (Depending on which type of installation will be used).
  • Page 21: Chain Tray Kit

    Installing the Chain Tray Kit A chain tray is recommended for gates longer than 20 ft. to support the weight of the chain. DoorKing offers a chain tray kit in sections to fit any length gate. (DoorKing P/N 2601-270 10 Ft. section)
  • Page 22: Section 2 - Ac Power To Operator(S)

    SECTION 2 - AC POWER TO OPERATOR(S) Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a licensed electrical contractor perform this work.
  • Page 23: High Voltage Terminal Connection

    2.2 High Voltage Terminal Connection • Route incoming AC power wire through the high voltage conduit and run wire in the operator as shown. • Be sure wiring is installed in accordance with local codes. Be sure to color code all wiring. •...
  • Page 24: Section 3 - Adjustments

    FULL OPEN OPEN TIMER Cycles the operator when pressed. Gate Power LED opens to full open position ONLY. It will use the Auto-Close DOORKING UL 325 4602-010 timer when turned ON. DIP-Switches Pages 25-27 UL 325 Terminal Dry Relay Contact...
  • Page 25: Dip-Switch Sw 1 And Sw 2 Settings

    3.2 DIP-Switch SW 1 and SW 2 Settings The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then turned back on for the new setting to take affect.
  • Page 26 SW 2 Switch 1 Switch 1 Determines if the output of the loop detector (DoorKing loop detectors only) plugged into the EXIT loop port will be sent directly to the microprocessor to open (or reverse a closing gate) the gate, or if the output is directed to Main Terminal #10 where it can be connected to other input terminals.
  • Page 27: Automatic Open / Close Limit Adjustment

    3.3 Automatic Open / Close Limit Adjustment The 9150’s open/close limits DO NOT have to be physically adjusted. Every time the 9150 is powered up, the first open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions. These positions are determined by the physical stops that have been installed (See section 1.2, page 10).
  • Page 28: Clutch Adjustment

    3.4 Clutch Adjustment In addition to the inherent reverse sensor, this operator is equipped with a mechanical slip clutch (UL 325 Type C) to further reduce the possibility of injury should an entrapment occur. DO NOT over tighten the clutch to compensate for a gate that is damaged, poorly constructed or too heavy.
  • Page 29: Section 4 - Entrapment And Safety Protection

    TIMER 2 - CLOSE Beam be turned ON for each device wired to 3 - OPEN Edge terminal. 4 - CLOSE Edge DOORKING 4602-010 RE VE LO OP M OV 1 - OPEN Beam STOP (Switch 1) S IN e of...
  • Page 30: Entrapment Protection Device Locations

    4.2 Entrapment Protection Device Locations Typical Photo Sensor mounting height If the distance between the gate and distance away from gate. and wall is greater than 2 1/4”. Filler Post or Barrier Secure Side Non-Secure Side Inside Property Outside Property 5”...
  • Page 31 Main 8 - Ground (Common) instruction sheet that comes Terminal 9 - CLOSE Edge/Beam REVERSE (Switch 4) with the receiver/transmitter DOORKING 4602-010 10 - Ground (Common) for more specific wiring and mounting instructions. UL 325 Terminal Connect ONLY MONITORED Devices...
  • Page 32: Loop Detector Wiring

    A loop detection system will sense a vehicle like a metal detector and send a signal to the gate operator preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. DoorKing recommends that a licensed installer perform this work.
  • Page 33: Section 5 - Wiring

    (Single channel) for a single operator. Terminal #10 connected to terminal #4 will FULLY open Dry Relay Contact bi-parting gates. Dual operators ONLY using DoorKing’s plug-in DUAL channel loop detector. (Page 32). Dry Relay Contact Operation of relay is dependent on setting of SW 1, switches 4 and 5.
  • Page 34: Control Wiring For Single/Primary Operator

    Key Switch Terminal Pages 25-27 Red Full Open Stand-Alone Green Close Keypad White Com 3-Button Control Station DoorKing ONLY Stand-Alone Card Reader Note: All stand-alone and Terminal #3 Note: telephone entry Exceeding 250 mA of power from devices must use a...
  • Page 35: Auxiliary Device Wiring

    DOORKING 4602-010 Gate Tracker (Quad Box Shown) DoorKing Access Control System (Model 1833, 1835, 1837 or 1838) tracker system can be connected.This system can keep track of gate operator cycle count, shorted inputs, loop detector problems, any forced entry attempts, if the gate has struck anything during the open or close cycle, power interruptions, etc.
  • Page 36: Bi-Parting Gates Wiring - Dual Gate Operators

    Automatic Orange REVERSE Exit Loop SENSITIVITY Main Terminal Main Terminal Interconnection Cable Sold separately from DoorKing. UL 325 Terminal Close Beam Red #3 #3 Red Close Beam Common Gray #4 #4 Gray Common Dual Channel Open Beam Note: Open Edge Blue #7...
  • Page 37: Section 6 - Operating Instructions

    SECTION 6 - OPERATING INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3.
  • Page 38: Shutdown Conditions

    6.2 Shutdown Conditions Under various entrapment conditions the operator will assume either a soft or hard (alarm) shutdown. To determine what type of reset action is required, you will need to understand how the different entrapment conditions affect the gate operator.
  • Page 39: Manual Gate Operation

    “chirp every 5 sec.” and the hard shutdown condition will remain in affect until the reset button is pushed. Note: DoorKing operators have a built-in alarm reset push button mounted on the operator above the power ON-OFF toggle switch. Activating this button will return the gate operator to normal operation, but will not cycle the gate operator.
  • Page 40 Fail-Secure Manual Release System (Owner Installed) This manual release system (Installed 2600-865 Fail-Secure Manual Release Kit) allows the gate to be manually operated ONLY after unlocking the gate operator. Power outages or turning power off WILL NOT allow gate to be manually operated without physically unlocking the gate operator with the key first.
  • Page 41: Section 7 - Maintenance And Troubleshooting

    Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or suspected. High cycle usage may require more frequent service checks. Contact servicing dealer. If you don’t know your servicing dealer, see DoorKing’s “DEALER LOCATOR” at www.DoorKing.com t c h...
  • Page 42: Troubleshooting

    5. If a three-button control station (open-close-stop) is connected to this gate operator, check for proper wiring. Only a DoorKing three button control station (P/N 1200-006 or 007) can be used with this gate operator. Others will cause a malfunction.
  • Page 43 Symptom Possible Solution Operator will not run, entrapment protection • The entrapment protection device has a fault or the wiring to it is shorted. input(s) LED is ON. Operator will not run, entrapment protection • The entrapment protection device is not connected or the wiring to it is open. input(s) LED is Blinking.
  • Page 44: Accessory Items

    7.3 Accessory Items UL 325 Monitored Entrapment Protection Devices available for model 9150 slide gate operator. Type B2 Contact Sensors (Reversing Edge) Miller Edge Sensing Edges - all models with a T2 (resistive) termination. Miller Edge Monitored Gate Link Model MGL-K20 Miller Edge wireless monitored transmitter/receiver kit model RB-G-K10 ASO GMBH Sentir GF Series sensing edges Type B1 Non-contact Sensors (Photo Cell)
  • Page 45: Model 9150 Wiring Diagrams

    Neu Hot Brown Alarm Black Black White White White Yellow Reset Neutral Power AC Power Convenience Outlets REVERSE LOOP EXIT LOOP FULL OPEN OPEN Board TIMER Ground Green Green Blue DOORKING 4602-010 White Yellow Black Blue Brown White REVERSE SENSITIVITY 9150-065-M-5-18...
  • Page 46 Brown Alarm Black Black White White White Yellow Reset Neutral Power AC Power Convenience Outlets REVERSE LOOP EXIT LOOP FULL OPEN OPEN Board TIMER Ground Green Green Orange DOORKING Yellow 4602-010 White Yellow Black Blue Brown White REVERSE SENSITIVITY 9150-065-M-5-18...
  • Page 47: Section 8 - Owner Of Gate Operator

    SECTION 8 - OWNER OF THE GATE OPERATOR 8.1 Alarm Sounding and Gate WILL NOT Operate A KEY has been supplied that will Note: The owner of the gate operator is responsible for unlock the power switch cover on the KEY availability. this gate operator.
  • Page 48: Manual Gate Operation

    8.2 Manual Gate Operation Caution: NEVER attempt to manually operate the gate until you have VERIFIED that power to the gate operator has been SHUT-OFF! Please read SECTION 6 - OPERATING INSTRUCTIONS for more information about operating this gate operator. Factory Equipped FAIL-SAFE Manual Operation Gate can be IMMEDIATELY manually operated (pushed open) during a power outage.
  • Page 49: Gate Operators Monthly Checkup

    If you feel uncomfortable performing any of these inspections or testing, a qualified service technician will perform the visual inspections and testing for you. You can find a trained service technician at DoorKing’s “Dealer Locator” at www.doorking.com Visual Inspection Visually inspect the rollers, fasteners, brackets and other gate hardware for proper alignment, proper tightness, and signs of damage, breakage, looseness, rust or wear.
  • Page 50 9150-065-M-5-18...
  • Page 52 The operator will not run without one or more monitored type B1 or B2 entrapment protection devices. THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. Visit www.dkslocator.com to find a professional installing and servicing dealer in your area. www.doorking.com DoorKing, Inc. 120 S. Glasgow Avenue Inglewood, California 90301 U.S.A.