1.9 Entrapment Protection Installation REQUIRED

A monitored photo sensor (Type B1) or monitored reversing edge (Type B2, see next page) MUST be installed or operator WILL
NOT function. A standard photo sensor can also be used as safety protection for the closing cycle of the gate, see below, but a
monitored photo sensor or monitored reversing edge MUST also be installed.
Standard Photo Sensor
Mounting Position
5"
or less
21"
Typical
27.5"
Max.
Monitored Photo Sensor
Mointored Sensor Note:
Input is active in both directions of travel.
Potential Entrapment Area:
If the OPENING gate could cause an entrapment,
then installation of a MONITORED entrapment
protection device is REQUIRED.
See page 25 for AUX terminal wiring
for monitored photo sensor.
Standard Photo Sensor
See page 24 for MAIN terminal wiring
for standard photo sensor.
6050-065-C-2-16
Monitored Photo Sensor Mounting Position
Opening Gate
Standard Photo Sensor
Potential Safety
Hazard Area
Closing Gate
Note: A STANDARD photo sensor cannot be
connected when using a SHADOW Loop.
UL sensor mounted just
above top of operator
Potential
Entrapment
Area
Monitored
Photo Sensor
Wall
13