See page 24 for main terminal wiring.
When gate is closed, input will open gate.
When gate is open and auto close timer
SW 1, switch 4 is turned ON, input will
re-set and hold timer.
When gate is open and auto close timer
SW 1, switch 4 is turned OFF, input will
close gate.
When gate is closing, input will reverse gate.
lf SW 1, switch 3 is ON, functions as a
normal full open input (Normal setting).
lf SW 1, switch 3 is OFF, input to
terminal #12 becomes the output from the
EXIT loop detector plugged into the EXIT
loop port. (Used for specialized functions).
This input ONLY functions when gate is fully
opened or in the closing cycle.
When gate is closing: SW 2, switch 5 is OFF, an
input to terminal #15 (e.g.: photo beam gets
obstructed) will reverse and open the gate.
Note: If the auto-close timer is ON, when
gate reaches the open position, timer will
not close the gate. Another input
command is needed to reset and close
the gate.
When gate is closing: SW 2, switch 5 is
ON, an input to terminal #15 (e.g.: photo
beam gets obstructed) has NO effect on the
gate operator (Set for Shadow input).
Operation of the circuit board dry relay
contact is dependent on setting of SW 1,
switches 1 and 2.
Relay contacts can be set for Normally
Open (NO) or
Normally Closed (NC)
operation.
Contact rating is
1 amp maximum
at 24-volts DC.
24-volt DC magnetic lock
power is provided constantly
except when the gate is
opening or open (Normally
Closed function). 1 Amp Max.
6050-065-C-2-16
QUICK GUIDE: Terminal Descriptions
SW1
SW1
12
SW1
15
SW1
N C
N O
18
Power - Neutral
Power - Neutral
11
Circuit Board Power
24 VAC - 250 ma. max.
12 VAC - 150 ma. max.
Pulse 1 - Primary Operator
Pulse 2 - Secondary Operator
Full Open/Open Loop
OPEN - DoorKing 3-Button station ONLY
CLOSE - DoorKing 3-Button station ONLY
Standard Reverse or Shadow
Dry Relay Contact
16
Dry Relay Contact
24 VDC Maglock Power
Low Voltage Common
Low Voltage Common
DANGER
HIGH VOLTAGE!
Motor
Motor
Not Used
10
11
Full Open
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
NC
NO