4.4

Lamp

1. Lamp Mode
2. Constant Power
3. Constant Intensity
4. Current Lamp
5. Lamp Auto Switch
6. Lamp Auto Switch Time
7. Lamp Info
8. Lamp Life Setting
9. Reset Lamp Hours
10. Light Sensor
Lamp Mode
Select Constant Power, Constant Intensity or ECO mode. When in ECO mode,
the projector will adjust to the lowest fan speed and switch the lamp power to
the minimum setting.
Constant Power
Set the value of the lamp power (in Watts).
Constant Intensity
Set the value for the Constant Intensity to maintain constant brightness.
The light sensor monitors the light level and applies more power as the lamp
brightness decays naturally over time. When the lamp setting reaches
maximum power of 465W, it remains at this setting. Note that the light sensor
needs to be calibrated for Constant Intensity mode to work properly. Calibration
should be performed again after every lamp change.
Current Lamp
Select which lamp(s) is in use.