Good Read Led Duration - Datalogic Gryphon I GD44XX Product Reference Manual

Hide thumbs Also See for Gryphon I GD44XX:
Table of Contents

Advertisement

Enter/Exit Programming Mode

Good Read LED Duration

This feature specifies the amount of time that the Good Read LED remains
on following a good read. The good read LED on time can be set within a
range of 100 milliseconds to 25,500 milliseconds (0.1 to 25.5 seconds) in
100ms increments. A setting of 00 keeps the LED on until the next trigger
pull.
See
ting this feature.
$CLAGL
Select Good Read LED Duration Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.
108
page 293
in "References" for detailed instructions and examples for set-
003 = Good Read LED
DEFAULT
stays on for 300 ms.
Indicators are dimmed during sleep.
$CLAGL00(CR)
Good Read LED Duration Setting =
Keep LED on until next trigger pull
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at left followed by the digits from the Alphanumeric
Appendix D, Keypad
characters in
your desired character(s). End by scanning the
ENTER/EXIT bar code again.
~
CANCEL
Gryphon™ I GD44XX/GBT4400/GM440X