Mitsubishi Electric MELSERVO MR-J2S- A Instruction Manual page 68

General-purpose ac servo general-purpose interface servo amplifier
Table of Contents

Advertisement

3. SIGNALS AND WIRING
Signal
Symbol
Alarm code
ACD 0
ACD 1
ACD 2
Connec-
tor pin
No.
CN1A
To use this signal, set "
19
This signal is output when an alarm occurs. When there is no
CN1A
alarm, respective ordinary signals (RD, INP, SA, ZSP) are output.
18
Alarm codes and alarm names are listed below:
CN1B
(Note) Alarm code
19
CN1B
CN1A
19 Pin
18 Pin
0
0
0
0
0
1
0
1
1
0
1
0
1
1
Note. 0: off
1: on
Functions/Applications
1 " in parameter No.49.
Alarm
CN1A
display
19 Pin
88888
Watchdog
AL.12
Memory error 1
AL.13
Clock error
AL.15
Memory error 2
AL.17
Board error
0
AL.19
Memory error 3
AL.37
Parameter error
Serial communication
AL.8A
timeout
AL.8E
Serial communication error
AL.30
Regenerative error
1
AL.33
Overvoltage
0
AL.10
Undervoltage
AL.45
Main circuit device
AL.46
Servo motor overheat
1
AL.50
Overload 1
AL.51
Overload 2
AL.24
Main circuit error
0
AL.32
Overcurrent
AL.31
Overspeed
Command pulse frequency
1
AL.35
alarm
AL.52
Error excessive
AL.16
Encoder error 1
AL.1A
Monitor combination error
0
AL.20
Encoder error 2
AL.25
Absolute position erase
3 - 21
I/O
division
DO-1
Name
Control
mode
P
S
T

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMr-j2s-*aMr-j2s- a seriesMr-j2s-20a

Table of Contents