13. OPTIONS AND AUXILIARY EQUIPMENT
(d) Line noise filter (FR-BLF, FR-BSF01)
This filter is effective in suppressing noises radiated from the power supply side and output side of
the servo amplifier and also in suppressing high-frequency leakage current (zero-phase current)
especially within 0.5MHz to 5MHz band.
Connection diagram
Wind the 3-phase wires by the equal number of times in the
same direction, and connect the filter to the power supply side
and output side of the servo amplifier.
The effect of the filter on the power supply side is higher as the
number of winds is larger. The number of turns is generally four.
If the wires are too thick to be wound, use two or more filters
and make the total number of turns as mentioned above.
On the output side, the number of turns must be four or less.
Do not wind the grounding wire together with the 3-phase wires.
The filter effect will decrease. Use a separate wire for grounding.
Example 1
NFB
Power
supply
Line noise
filter
(Number of turns: 4)
Example 2
MC
NFB
Power
supply
Line noise
filter
Two filters are used
(Total number of turns: 4)
(e) Radio noise filter (FR-BIF)...for the input side only
This filter is effective in suppressing noises radiated from the power supply side of the servo
amplifier especially in 10MHz and lower radio frequency bands. The FR-BIF is designed for the
input only.
Connection diagram
Make the connection cables as short as possible.
Grounding is always required.
When using the FR-BIF with a single-phase wire,
always insulate the wires that are not used for wiring.
NFB
Power
supply
Radio noise
filter FR-BIF
MC
Servo amplifier
L
1
L
2
L
3
Servo amplifier
L
1
L
2
L
3
Servo amplifier
MC
L
1
L
2
L
3
Outline drawing [Unit: mm] ([Unit: in.])
FR-BSF01(for MR-J2S-200A or less)
Approx.95 0.5(3.74 0.02)
FR-BLF(MR-J2S-350A or more)
Outline drawing (Unit: mm) ([Unit: in.])
Red
White
Blue
29 (1.14)
58 (2.28)
13 - 49
Approx.110(4.33)
2- 5(0.20)
Approx.65(2.56)
33(1.30)
7(0.28)
130(5.12)
85(3.35)
160(6.30)
180(7.09)
Leakage current: 4mA
Green
29 (1.14)
44 (1.73)
5 (0.20)
hole
7 (0.28)