11. OUTLINE DIMENSION DRAWINGS
(c) Insulation displacement type
Model
Connector
: 10120-6000EL
Shell kit
: 10320-3210-000
2- 0.5
20.9(0.82)
(0.02)
29.7
(1.17)
(2) Bus cable connector
<Honda Tsushin Industry>
PCR-LS20LA1
13.0
(0.51)
23.0(0.91)
27.4(1.08)
32.0(0.91)
Number of Pins
PCR-S20FS (soldering type)
20
PCR-S20F (insulation displacement type)
Note. PCR-S20F and PCR-LS20LA1W are not options and are to be supplied by the customer.
[Unit: mm]
( 0.26)
6.7
([Unit: in])
Logo, etc. are indicated here.
14.2(0.56)
(0.04)1 12.2
1(0.04)
(0.48)
RS
Connector
PCR-LS20LA1W
27.4(1.08)
32.0(0.91)
Model
Case
PCR-LS20LA1
PCR-LS20LA1W
11 - 9
[Unit: mm]
([Unit: in])
10.4(0.41)
RS
1.9
1
12.2
1
(0.08)
(0.48)
(0.04)
(0.04)
Crimping terminal
FHAT-002A