Mitsubishi Electric MELSERVO MR-J2S- A Instruction Manual page 150

General-purpose ac servo general-purpose interface servo amplifier
Table of Contents

Advertisement

5. PARAMETERS
(2) Set content
The servo amplifier is factory-set to output the servo motor speed to analog monitor 1 (MO1) and the
torque to analog monitor (MO2). The setting can be changed as listed below by changing the
parameter No.17 value:
Refer to Appendix 2 for the measurement point.
Setting
Output item
0
Servo motor speed
1
Torque(Note2)
2
Servo motor speed
3
Torque(Note2)
4
Current command
5
Command pulse
frequency
Note1. Encoder pulse unit.
2. 8V is outputted at the maximum torque.However, when parameter No.28 76 are set to limit torgue, 8V is outputted
at the torque highly limited.
Description
CCW direction
8[V]
Max. speed
0 Max. speed
8[V]
CW direction
Driving in CCW direction
8[V]
Max. torque
0 Max. torque
8[V]
Driving in CW direction
CW
CCW
8[V]
direction
direction
Max. speed
0 Max. speed
Driving in
Driving in
8[V]
CW direction
CCW direction
Max. torque
0 Max. torque
CCW direction
8[V]
Max. command
current
(Max. torque
command)
0 Max. command
current
(Max. torque
command)
8[V]
CW direction
CCW direction
10[V]
500kpps
0
500kpps
10[V]
CW direction
Setting
Output item
6
Droop pulses
(Note1)
( 10V/128pulse)
7
Droop pulses
(Note1)
( 10V/2048pulse)
8
Droop pulses
(Note1)
( 10V/8192pulse)
9
Droop pulses
(Note1)
( 10V/32768pulse)
A
Droop pulses
(Note1)
( 10V/131072pulse)
B
Bus voltage
5 - 31
Description
CCW direction
10[V]
128[pulse]
0
128[pulse]
10[V]
CW direction
CCW direction
10[V]
2048[pulse]
0 2048[pulse]
10[V]
CW direction
CCW direction
10[V]
8192[pulse]
0 8192[pulse]
10[V]
CW direction
CCW direction
10[V]
32768[pulse]
0 32768[pulse]
10[V]
CW direction
CCW direction
10[V]
131072[pulse]
0
131072[pulse]
10[V]
CW direction
8[V]
0
400[V]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMr-j2s-*aMr-j2s- a seriesMr-j2s-20a